IEI MiniMax 3 Installation/Programming Manual Section 3: Programming
3.20 Programming Options Chart
The following chart is a complete list of programming commands available in the Max 3 Door Control Module. This chart is for quick
reference. Please refer to the preceding sections for complete details of each command. Defaults are in bold.
Table 6: Programming Options Chart
Action Desired
Press
Details
Enter Program Mode
99 # (Master Code)*
Yellow LED blinks slowly
Change master code
1 # (new code) * (repeat code) *
Ex: 1 # 4321 * 4321 *
Code-only operation
Add Supervisor Code
2 # (new code) * (repeat code) *
Ex: 1 # 6478 * 6478 *
Code-only operation
Set Main Relay Time
11 # time # 0 # **
Time =1-99 seconds
(default = 5
seconds)
Set/clear standard option
30 # option # s/c # **
See Chart below
Option
Set
Clear
0 – Audio Keypress Feedback
0 = Disabled
1 = Enabled
1 – Visual Keypress Feedback
0 = Disabled
1 = Enabled
5 – User Lockout Enable
0 = Disabled
1 = Enabled
9 – Time Zone Select
0 = Disabled
1 = Enabled
11 – Auto-Unlock Select
0 = Disabled
1 = Enabled
12 – First-In Auto-Unlock
0 = Disabled
1 = Enabled
13 – Daylight Savings Time
0 = Disabled
1 = Enabled
15 – Daylight Savings Time Format
0 = US
1 = European
16 – WFE LED Output Select
0 = Active Low
1 = Active High
17 – WFE Sounder Output Select
0 = Active Low
1 = Active High
18 – Control Module Audio Indicators
0 = Disabled
1 = Enabled
Change Platform Parameters
32 # parameter # value # **
See Chart Below
Parameter
Value
0 – Error Lockout Threshold
1 – 50 Attempts
(Default = 3)
1 – Error Lockout Duration
1-255 Sec.
(Default = 10 Sec.)
3 – Extended User Unlock Time
1-255 Sec.
(Default = 10 Sec.)
4 – Facility Code (For commands 51 & 57)
0 – 255
(Default = 11)
Set System Time
41 # hhmm # 0 # **
hhmm=hour/minute (24 Hour Format)
Set System Date
42 # mmddyy # dow # **
mmddyy=month, date, year; dow=day
of week, 1=Sunday
Set Door Number
43 # 0 # Door Number # **
Set Door Ajar Time
44 # time # 0 # **
Time =door ajar time, to nearest 10’s
seconds, entered as 30-990;
(default=30 secs)
Document #: 6055672, Rev 1.0 D1c Page 43 of 48