IEI MiniMax 3 Installation/Programming Manual Section 3: Programming
3.18 Reseting System Defaults and Erasing Memory
There are two methods for deleting programmed information from the Max 3 Door Control Module. The first method is using
command 40, which resets the system defaults and the master code only. The second method is through command 46, which erases all
the memory in the unit, except the transaction log.
3.18.1 Resetting the Master Code and System Defaults Only
Entering command 40 erases everything from memory except the user list and transaction log and restores the default settings. This is
useful if the unit has experienced programming problems, or wish to delete earlier programming.
Action
Command
Enter Program Mode
99 # master code *
Reset System Defaults
40 # 00000 # 00000 # * *
Exit Program Mode
*
3.18.2 Erasing Entire Memory/Resetting System Defaults
Entering command 46 deletes everything from memory including the user list but not the transaction log and restores the default
settings. This is used as a last resort if you need to erase a specific user and do not have a programmed user list.
Action
Command
Enter Program Mode
99 # master code *
Erase Entire Memory
46 # 00000 # 00000 # * *
Exit Program Mode
*
3.18.3 Erasing the Transaction Event Log
If you need to erase the transaction event log use command 76. Once you've done this command the transaction log is erased
permanently.
Action
Command
Enter Program Mode
99 # master code *
Erase Transaction Event Log
76 # 00000 # 00000 # * *
Exit Program Mode
*
Document #: 6055672, Rev 1.0 D1c Page 41 of 48
Note:
The PC software is required to view the transaction log.