p.42
PRODUCT INSTALLATION
iTDC
device.
Connect Anti-inverse voltage diode between (+) wire and (-) wire
of door lock.
Alarm
C12V wire of DC12V power device to R2COM port of
iTDC/iTDC-SR main board.
Connect (+) wire of alarm to R2NO port of iTDC/iTDC-SR main
board.
Connect (-) wire of alarm to GND (-) wire of DC12V power device.
Connect Anti-inverse voltage diode between (+) wire and (-) wire
of alarm.
Door 2
Door Lock
C12V wire of DC12V power device to R3COM port of
iTDC/iTDC-SR main board.
Connect (+) wire of door lock to R3NO port of iTDC/iTDC-SR main
board.
Connect (-) wire of door lock to GND (-) wire of DC12V power
device.
Connect Anti-inverse voltage diode between (+) wire and (-) wire
of door lock.
Alarm
C12V wire of DC12V power device to R4COM port of
iTDC/iTDC-SR main board.
Connect (+) wire of alarm to R4NO port of iTDC/iTDC-SR main
board.
Connect (-) wire of alarm to GND (-) wire of DC12V power device.
Connect Anti-inverse voltage diode between (+) wire and (-) wire
of alarm.
Содержание iTDC
Страница 1: ...USER MANUAL iTDC 2 4 DOOR ACCESS CONTROL SYSTEM ...
Страница 20: ...FEATURES iTDC p 13 3 DIMENSION Unit inch mm ...
Страница 22: ...FEATURES iTDC p 15 Internal TCP IP Module IIM100 ...
Страница 37: ...PRODUCT INSTALLATION 6 p 30 1 DESCRIPTION OF PORTS FOR WIRING 1 1 ITDC ITDC SR MAIN BOARD PORT ...
Страница 79: ...p 72 SETTING CHANGES iTDC ...
Страница 87: ...p 80 SETTING CHANGES iTDC ...
Страница 101: ...p 94 SETTING CHANGES iTDC 3 SETTING MENU F3 ...
Страница 112: ...SETTING CHANGES iTDC p 105 ARM CODE PROCESS DETAILS ARM CODE has to be different from DISARM CODE ...
Страница 113: ...p 106 SETTING CHANGES iTDC DISARM CODE PROCESS DETAILS ARM CODE has to be different with DISARM CODE ...
Страница 117: ...p 110 SETTING CHANGES iTDC ...
Страница 135: ...p 128 APPENDIX iTDC But two functions 1 2 cannot be used at the same time ...