p.40
PRODUCT INSTALLATION
iTDC
Power Fail Secure Mode
It closes door automatically when power to door lock is disconnected.
Security level becomes high because all the doors are closed in this situation so
somewhere as bank safe is required to install Power Fail Secure Mode.
Power Fail Safe Mode
It opens door automatically when power to door lock is disconnected.
Security level becomes low because all the doors are opened in this situation, so
somewhere as exit is required to install Power Fail Safe Mode.
7.1
2-Door Control
Wiring for door lock and alarm in Power Fail Safe Mode
Door 1
Door Lock
C12V wire of DC12V power device to R1COM port of
iTDC/iTDC-SR main board.
Connect (+) wire of door lock to R1NC port of iTDC/iTDC-SR main
board.
Connect (-) of door lock to GND (-) wire of DC12V power device.
Connect anti-inverse voltage diode between (+) wire and (-) wire
of door loack.
Alarm
C12V wire of DC12V power device to R2COM port of
iTDC/iTDC-SR main board.
Connect (+) wire of alarm to R2NO of iTDC/iTDC-SR main board.
Connect (-) wire of alarm to GND (-) wire of DC12V power device.
Connect anti-inverse voltage diode between (+) wire and (-) wire
of alarm.
Door 2
Door Lock
Connect DC12V +12V wire of DC12V power device to R3COM
port of iTDC/iTDC-SR main board.
Connect (+) wire of door lock to R3NC port of iTDC/iTDC-SR main
board.
Connect (-) wire of door lock to GND (-) wire of DC12V power
device.
Содержание iTDC
Страница 1: ...USER MANUAL iTDC 2 4 DOOR ACCESS CONTROL SYSTEM ...
Страница 20: ...FEATURES iTDC p 13 3 DIMENSION Unit inch mm ...
Страница 22: ...FEATURES iTDC p 15 Internal TCP IP Module IIM100 ...
Страница 37: ...PRODUCT INSTALLATION 6 p 30 1 DESCRIPTION OF PORTS FOR WIRING 1 1 ITDC ITDC SR MAIN BOARD PORT ...
Страница 79: ...p 72 SETTING CHANGES iTDC ...
Страница 87: ...p 80 SETTING CHANGES iTDC ...
Страница 101: ...p 94 SETTING CHANGES iTDC 3 SETTING MENU F3 ...
Страница 112: ...SETTING CHANGES iTDC p 105 ARM CODE PROCESS DETAILS ARM CODE has to be different from DISARM CODE ...
Страница 113: ...p 106 SETTING CHANGES iTDC DISARM CODE PROCESS DETAILS ARM CODE has to be different with DISARM CODE ...
Страница 117: ...p 110 SETTING CHANGES iTDC ...
Страница 135: ...p 128 APPENDIX iTDC But two functions 1 2 cannot be used at the same time ...