PRODUCT INSTALLATION
iTDC
p.43
7.2
3-Door control
Firstly equip I/O board (EIO88) to iTDC/iTDC-SR then wire. Door 1 is controlled by main board
of iTDC/iTDC-SR and door 2, 3 are controlled by I/O board (EIO88).
Door 1
Door Lock
Connect to RL1 port of iTDC/iTDC-SR main board.
(Check the wiring type between POWER FAIL SAFE and POWER
FAIL SECURE)
Alarm
Connect to RL2 port of iTDC/iTDC-SR main board.
Door 2
Door Lock
Connect to OUT1 port of EIO88
(Check the wiring type between POWER FAIL SAFE and POWER
FAIL SECURE)
Alarm
Connect to OUT2 port of EIO88
Door 3
Door Lock
Connect to OUT3 port of EIO88 (Check the wiring type between
POWER FAIL SAFE and POWER FAIL SECURE)
Alarm
Connect OUT4 port of EIO88.
7.3
4-Door Control
Firstly equip I/O board (EIO88) to iTDC/iTDC-SR then wire. Door 1 and 2 are controlled by
main board of iTDC/iTDC-SR and door 3 and 4 are controlled by I/O board (EIO88).
Door 1
Door Lock
Connect to RL1 port of iTDC/iTDC-SR main board.
(Check the wiring type between POWER FAIL SAFE and POWER
FAIL SECURE)
Alarm
Connect to RL2 port of iTDC/iTDC-SR main board.
Door 2
Door Lock
Connect to RL3 port of iTDC/iTDC-SR main board.
(Check the wiring type between POWER FAIL SAFE and POWER
FAIL SECURE)
Alarm
Connect to RL4 port of iTDC/iTDC-SR main board.
Door 3
Door Lock
Connect to OUT1 port of EIO88
(Check the wiring type between POWER FAIL SAFE and POWER
FAIL SECURE)
Alarm
Connect to OUT2 port of EIO88
Door 4
Door Lock
Connect to OUT3 port of EIO88
(Check the wiring type between POWER FAIL SAFE and POWER
FAIL SECURE)
Alarm
Connect to OUT4 port of EIO88
Содержание iTDC
Страница 1: ...USER MANUAL iTDC 2 4 DOOR ACCESS CONTROL SYSTEM ...
Страница 20: ...FEATURES iTDC p 13 3 DIMENSION Unit inch mm ...
Страница 22: ...FEATURES iTDC p 15 Internal TCP IP Module IIM100 ...
Страница 37: ...PRODUCT INSTALLATION 6 p 30 1 DESCRIPTION OF PORTS FOR WIRING 1 1 ITDC ITDC SR MAIN BOARD PORT ...
Страница 79: ...p 72 SETTING CHANGES iTDC ...
Страница 87: ...p 80 SETTING CHANGES iTDC ...
Страница 101: ...p 94 SETTING CHANGES iTDC 3 SETTING MENU F3 ...
Страница 112: ...SETTING CHANGES iTDC p 105 ARM CODE PROCESS DETAILS ARM CODE has to be different from DISARM CODE ...
Страница 113: ...p 106 SETTING CHANGES iTDC DISARM CODE PROCESS DETAILS ARM CODE has to be different with DISARM CODE ...
Страница 117: ...p 110 SETTING CHANGES iTDC ...
Страница 135: ...p 128 APPENDIX iTDC But two functions 1 2 cannot be used at the same time ...