Troubleshooting
iTDC
p.131
1.
Check if communication ID set in the device is same with communication ID set in a
software.
See
[Setting Changes] > [SETUP MENU F2] > [COMM ID(COMMUNICATION ID, BOARD
ID) DISPLAY]
and check a communication address set in the device.
2.
When you use several devices together, communication addresses set in the devices
should be different from each other.
3.
Check if baud rate is same with baud rate set in a software.
See
[Setting Changes] > [SETUP MENU F2] > [Baud Rate Setting]
and check baud rate set
in the device.
* If you initialize the device, baud rate is set to
9,600
bps which is the default.
1.3
Please check if the communication port setting is good.
Check if communication port set in software is same with communication port set in PC.
1.4
Please check if the termination resistor is connected.
For long distance communication of RS422 or RS485, a resistor is connected to match
impedance to reduce distortion and attenuation which are caused by delay. This resistor is
called termination register.
In the case that several controllers are installed, the termination resistor should be
connected to the last controller and the last controller only.
Resistors below 90Ω are not used as a terminal resistor.
Содержание iTDC
Страница 1: ...USER MANUAL iTDC 2 4 DOOR ACCESS CONTROL SYSTEM ...
Страница 20: ...FEATURES iTDC p 13 3 DIMENSION Unit inch mm ...
Страница 22: ...FEATURES iTDC p 15 Internal TCP IP Module IIM100 ...
Страница 37: ...PRODUCT INSTALLATION 6 p 30 1 DESCRIPTION OF PORTS FOR WIRING 1 1 ITDC ITDC SR MAIN BOARD PORT ...
Страница 79: ...p 72 SETTING CHANGES iTDC ...
Страница 87: ...p 80 SETTING CHANGES iTDC ...
Страница 101: ...p 94 SETTING CHANGES iTDC 3 SETTING MENU F3 ...
Страница 112: ...SETTING CHANGES iTDC p 105 ARM CODE PROCESS DETAILS ARM CODE has to be different from DISARM CODE ...
Страница 113: ...p 106 SETTING CHANGES iTDC DISARM CODE PROCESS DETAILS ARM CODE has to be different with DISARM CODE ...
Страница 117: ...p 110 SETTING CHANGES iTDC ...
Страница 135: ...p 128 APPENDIX iTDC But two functions 1 2 cannot be used at the same time ...