p.26
PREPARATION OF INSTALLATION
iTDC
8 conductor, shielded
4
Door Lock, Alarm Device
Lock (Alarm) ↔ iTDC/iTDC-SR
Belden #9409, 18AWG
2 conductor, unshielded
300m
5
RS232 Cable
Converter ↔ Host P.C.
Belden #9829, 24 AWG
2-twisted pair, shielded
15m
6
RS485 Cable
iTDC/iTDC-SR ↔ iTDC/iTDC-SR
iTDC/iTDC-SR ↔ Converter
Belden #9829, 24 AWG
2-twisted pair, shielded
1,200m
RS422 Cable
iTDC/iTDC-SR ↔ iTDC/iTDC-SR
iTDC/iTDC-SR ↔ Converter
Belden #9830, 24 AWG
3-twisted pair, shielded
7
UTP Cable
Host PC ↔ HUB
HUB ↔ iTDC/iTDC-SR
UTP Cable CAT5(Catagory5)
100m
Reference
Description
Cable Specification
Maximum
Distance
For Reader of reference 2, you have to use wire that thick enough to bear higher
current than maximum consuming current.
3
HOW TO EQUIP OPTIONAL SPECIFICATION
You must connect LCD module on none power status otherwise the LCD module
may has trouble to operate.
3.1
EQUIPMENT OF TCP/IP MODULE (IIM100)
Please check to correct direction to equip optional TCP/IP module (IIM100). See figure below.
Содержание iTDC
Страница 1: ...USER MANUAL iTDC 2 4 DOOR ACCESS CONTROL SYSTEM ...
Страница 20: ...FEATURES iTDC p 13 3 DIMENSION Unit inch mm ...
Страница 22: ...FEATURES iTDC p 15 Internal TCP IP Module IIM100 ...
Страница 37: ...PRODUCT INSTALLATION 6 p 30 1 DESCRIPTION OF PORTS FOR WIRING 1 1 ITDC ITDC SR MAIN BOARD PORT ...
Страница 79: ...p 72 SETTING CHANGES iTDC ...
Страница 87: ...p 80 SETTING CHANGES iTDC ...
Страница 101: ...p 94 SETTING CHANGES iTDC 3 SETTING MENU F3 ...
Страница 112: ...SETTING CHANGES iTDC p 105 ARM CODE PROCESS DETAILS ARM CODE has to be different from DISARM CODE ...
Страница 113: ...p 106 SETTING CHANGES iTDC DISARM CODE PROCESS DETAILS ARM CODE has to be different with DISARM CODE ...
Страница 117: ...p 110 SETTING CHANGES iTDC ...
Страница 135: ...p 128 APPENDIX iTDC But two functions 1 2 cannot be used at the same time ...