Page | 50
•
When a
Cancel
command is sent, the L100 quits the work state.
•
The response body depends on the command (75 46 25). If the related parameter is not 0, the
response data is only the ASCII code for the pressed keys.
8.1
LCD Group (Task)
8.1.1
Clear Display
Command Body:
8A 46 01 <Control>
Command Example
STX
Len
Low
Len
High
Command Body
LRC
CHK
SUM
ETX
02
0C
00
8A 46 01 <Control>
EA
46
03
Output Hex String: 0204008a4601ff32d003
<Control> 0:First Line 1:Second Line 2:Third Line 3:Fourth Line
0xFF: All Screen
Response Body:
06