Page | 75
13
Appendix C: Clearing the Log
The SmartPIN L100 maintains a log file of administrative events. When this log file becomes full (after
approximately 45 logged events), the L100 may fail to enter the Removal Detection mode or may beep
twice, then pause, then beep once, when the user attempts to enter a password (indicating that the Log
is full).
To clear the Log, send the
78 52 01 51
command to the L100. To do so, follow this procedure:
1.
Connect the L100 to the Spectrum Pro using the serial-to-RJ cable.
2.
Place the Spectrum Pro in pass-through mode using a
72 46 20 01 00 01
command. A quick way
to do this is to launch the
Windows-based U-Demo program (Universal SDK Demo)
Device > Send Data Command
from the command tree on the left, as shown below.
3.
Enter the command in the text area (see item 2, above) and select the
Wrap as NGA
checkbox
to ensure that the command is properly formatted to send to the device.
4.
Click
Execute Command
(item 3) and verify that the command was sent (item 4).
5.
After the Spectrum Pro is in pass-through mode, enter the
Clear Logs
command,
78 52 01 51
, in
the text area, and click
Execute Command
. See graphic below (items 1, 2, and 3).