Page | 39
o
<State> is 0x30 (Fix) or 0x31 (Removal) or 0x32 (Illegal Removal) Year, Month, Date,
Hour, and Minute need be ASCII code.
Note:
The Max Records is 40. After response this command, all Records are deleted.
8.8.15
Enter Stop Mode
Command Body:
78 46 72 01
Command Example
STX
Len
Low
Len
High
Command Body
LRC
CHK
SUM
ETX
02
04
00
78 46 72 01
4D
31
03
Output Hex String: 020400784672014D3103
Response Body:
06.
Note:
1.
Sets device enter to Stop Mode. In this mode, LCD display and backlight are off. Stop Mode
reduces power consumption to the lowest possible level. An L100 in Stop Mode can only be
woken up by a physical key press.
2.
Stop Mode cannot be reached from Bootloader mode, Diagnosis mode, Get PIN, Get Numeric,
Get Function Key, Get PIN for Pro, Display and Get Key for Pro and Active PINpad,
Activate/Deactivate Passwords, load cert, load key and load important data for PINpad mode.
8.8.16
Set Enter Sleep Mode Time
Enter Sleep Mode timeout period (the period after which the L100, if idle, goes to sleep); default is 120
seconds.
Command Body:
78 46 71 <TimeH> <TimeL>
Command Example
STX
Len
Low
Len
High
Command Body
LRC
CHK
SUM
ETX
02
05
00
78 46 71 <TimeH> <TimeL>
62
5C
03
Output Hex String: 020500784671012C625C03
<TimeH><TimeL>: Enter sleep mode time. After TimeH*256+TimeL seconds, device enters Sleep Mode.
Response Body:
06.
Note:
1.
Sleep Mode is controlled by a timeout after the L100 is idle for a specified time.
2.
Sleep Mode reduces power consumption to a much lower level, but the device remains capable
of being woken up by key press or communication from the host.