266
©2018 Integrated Device Technology, Inc
September 12, 2018
8A3xxxx Family Programming Guide
PWM_USER_DATA.PWM_DST_DECODER_ID
The ID of the destination PWM decoder.
PWM_USER_DATA.PWM_USER_DATA_SIZE
-
PWM_USER_DATA.PWM_USER_DATA_CMD_STS
PWM user data command and status register.
TRIGGER: Writing to this byte triggers a read and activation of all the bytes of the PMW_USER_DATA module.
Table 352: PWM_USER_DATA.PWM_DST_DECODER_ID Bit Field Locations and Descriptions
Offset
Address
(Hex)
PWM_USER_DATA.PWM_DST_DECODER_ID Bit Field Locations
D7
D6
D5
D4
D3
D2
D1
D0
001h
DECODER_ID[7:0]
PWM_USER_DATA.PWM_DST_DECODER_ID Bit Field Descriptions
Bit Field Name
Field Type Default Value
Description
DECODER_ID[7:0]
R/W
0
PWM decoder identification.
Use 0xFF for broadcast transmission.
Table 353: PWM_USER_DATA.PWM_USER_DATA_SIZE Bit Field Locations and Descriptions
Offset
Address
(Hex)
PWM_USER_DATA.PWM_USER_DATA_SIZE Bit Field Locations
D7
D6
D5
D4
D3
D2
D1
D0
002h
BYTES[7:0]
PWM_USER_DATA.PWM_USER_DATA_SIZE Bit Field Descriptions
Bit Field Name
Field Type Default Value
Description
BYTES[7:0]
R/W
0
The PWM user data length in bytes, from 1 to 128.
Indicates the number of bytes received or to be transmitted through
OTP_EEPROM_PWM_BUFF.
Table 354: PWM_USER_DATA.PWM_USER_DATA_CMD_STS Bit Field Locations and Descriptions
Offset
Address
(Hex)
PWM_USER_DATA.PWM_USER_DATA_CMD_STS Bit Field Locations
D7
D6
D5
D4
D3
D2
D1
D0
003h
COMMAND_STATUS[7:0]