SE2L User’s Manual (SE9Z-B1865)
21
3.5 Area switching
A maximum of 32 sets of area can be configured in SE2L. However the maximum configurable area
number differs depending on the selected function such as, muting and dual protection. Table 3-1 shows the
maximum configurable area number according to the used mode.
External input signals are provided in SE2L for switching the area. Each signal has a pair of normal and
inverted signal. For example, it is necessary to provide both input signal
IN_A
and inverse
IN_A
signal to
switch the area. Error will occur if IN_A and inverse IN_A signals do not complement each other. Table 3-2
below shows the combination of input signal to switch the area. Area in use will be displayed in the 7
segment LED of SE2L.
It is also possible to configure area input delay. Configure the necessary delay required for the system to
provide stable input signals to SE2L. The default value is 30ms.
There are maximum 5 input pairs (a pair is combination of normal and inverted signal) in SE2L therefore,
it can operate with maximum 32 sets of area. Further, it is also possible to switch the area through the speed
monitoring of increment encoder signal connected to SE2L
(
page 24
).
Table 3-1 Input combination for area switching
Mode
Protection
Max internal input
Max Area
Max encoder area
1 5
32
-
Standard
2 5
32
-
1 4
16
-
EDM
2 4
16
-
1 2
4
-
MUTING / EDM
2 1
2
-
Encoder
*1
1 2
3
32
*2
*1: Muting function and dual protection mode cannot be used if encoder input mode is selected.
*2: Among the 4 input patterns, at least one pattern must be used for encoder input. Other 3 remaining
patterns can be selected to be used as static input or not in use. A pattern with encoder input mode can
have maximum 32 sets of area (for detail, refer to section 3.6.4).
Содержание SE2L-H05LPC
Страница 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Страница 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Страница 103: ...SE2L User s Manual SE9Z B1865 102 Figure 7 34 a Project report tab Figure 7 34 b Error report tab...
Страница 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Страница 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Страница 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Страница 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Страница 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Страница 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Страница 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...