5.4 Limited detection capability zone
The limited detection capability zone is defined as a region between the optical window and start of the
detection zone. The limited detection capability zone of the SE2L is 90mm
from the origin of SE2L (Figure
5-9). Presence of object with low reflectance may not be detected in this zone.
Figure 5-9
Limited detection capability zone
Measured value will be longer than actual distance of the object if the
background is
highly reflective. Additional distance should be included when
configuring the protection zone.
High reflective background (Ex.: Mirror, corner cube reflector, reflective safety
jacket, road reflector) should be avoided. Reflectance caused by these materials
could lead to false detection in the protection zone.
Verify the configured areas before actual operation.
Failing to comply with the above could lead to critical injury or death.
User should perform risk assessment for possibility of object penetration into
the limited detection capability zone.
Содержание SE2L-H05LPC
Страница 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Страница 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Страница 103: ...SE2L User s Manual SE9Z B1865 102 Figure 7 34 a Project report tab Figure 7 34 b Error report tab...
Страница 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Страница 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Страница 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Страница 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Страница 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Страница 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Страница 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...