SE2L User’s Manual (SE9Z-B1865)
49
4.2 Access protection (Stationary Horizontal application with Dual
Protection zone)
In this kind of application, SE2L is mounted horizontally to simultaneously protect two hazardous areas
(Figure 4-4). Protection zones are configured around the hazardous area to prevent the entry of human
beings or object. Warning zone cannot be configuration in dual protection mode. Any objects or human
beings detected in the protection zones will switch the respective OSSD signal to OFF state from ON-state.
In this configuration it is possible to protect two equipments using a single SE2L.
The safety distance for this application is shown in figure 4-1.
Figure 4-4 Example Horizontal application of access protection (Dual protection zone)
4.3 Access protection (Vertical application- whole body detection)
SE2L can be used as a protective shield by mounting it vertically (Figure 4-5). Application shown in the
figure is generally used in preventing the access to hazardous area. When an object or human enter the
passage, OSSD signal will switch from ON-state to OFF-state.
In this configuration, SE2L detects objects or human beings in vertical plane. It is not possible to detect an
object or human being at the front or back side of the detection plane. Therefore, caution should be taken
while setting the distance between the detection plane and hazardous area. Configure the shortest response
time of SE2L not exceeding 90ms, Always use reference monitoring function in such applications to detect
the displacement of fences and SE2L which may expose the hazardous area. OSSD signal will switch to OFF
state when the position of reference is changed. The safety distance for this application is shown in figure
4-6 and 4-7.
Figure 4-5 Example of access protection (Whole body detection)
Protection zone 1
Protection zone 2
Содержание SE2L-H05LPC
Страница 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Страница 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Страница 103: ...SE2L User s Manual SE9Z B1865 102 Figure 7 34 a Project report tab Figure 7 34 b Error report tab...
Страница 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Страница 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Страница 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Страница 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Страница 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Страница 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Страница 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...