![IDEC MICROSmart FC5A Series Скачать руководство пользователя страница 257](http://html.mh-extra.com/html/idec/microsmart-fc5a-series/microsmart-fc5a-series_user-manual_617369257.webp)
22:
M
ODEM
M
ODE
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
22
‐
9
Preparations
for
Using
Modem
Before
using
a
modem,
read
the
user’s
manual
for
your
modem.
The
required
initialization
string
depends
on
the
model
and
make
of
the
modem.
When
the
MicroSmart
starts
to
run
the
user
program,
the
default
modem
initialization
strings
is
stored
to
D8145
‐
D8169.
See
Default
Initialization
String:
ATE0Q0V1&D2&C1\V0X4&K3\A0\N5S0=2&W
Programming
Data
Registers
and
Internal
Relays
To
enable
the
modem
mode
and
communicate
through
the
telephone
line,
the
following
settings
are
needed.
1.
If
the
default
initialization
string
does
not
match
your
modem,
program
a
proper
initialization
string
and
enter
the
ASCII
val
‐
ues
to
data
registers
starting
with
D8145
(initialization
string).
To
send
out
the
new
initialization
string,
turn
on
internal
relay
M8050
(initialization
string
start
IR)
after
the
new
values
have
been
stored
to
the
data
registers.
2.
Program
to
move
0
or
1
to
data
register
D8103
(online
mode
protocol
selection)
to
select
maintenance
protocol
or
user
pro
‐
tocol
for
the
RS232C
port
2
after
telephone
line
is
connected.
3.
Program
the
destination
telephone
number
if
dialing
is
required.
Enter
the
ASCII
values
of
the
telephone
number
to
data
registers
starting
with
D8170
(telephone
number).
Store
two
characters
each
in
one
data
register.
Enter
0Dh
at
the
end
of
the
telephone
number.
See
4.
If
you
want
to
change
the
default
value
of
3
retry
cycles,
program
to
move
a
required
value
to
data
register
D8109.
5.
Include
internal
relays
M8050
‐
M8077
in
the
user
program
to
control
the
modem
communication
as
required.
Setting
Up
the
CPU
Module
1.
Install
the
RS232C
communication
adapter
(FC4A
‐
PC1)
to
the
port
2
connector
on
the
all
‐
in
‐
one
type
CPU
module.
When
using
any
slim
type
CPU
module,
mount
the
RS232C
communication
module
(FC4A
‐
HPC1)
next
to
the
slim
type
CPU
module,
and
use
the
port
2
on
the
RS232C
communication
module.
When
using
the
HMI
base
module
with
any
slim
type
CPU
module,
install
the
RS232C
communication
adapter
(FC4A
‐
PC1)
to
the
port
2
connector
on
the
HMI
base
module.
2.
Connect
the
MicroSmart
CPU
module
port
2
to
a
modem
using
the
modem
cable
1C
(FC2A
‐
KM1C)
as
shown
on
CR LF
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...