22:
M
ODEM
M
ODE
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
22
‐
3
Special
Data
Registers
for
Modem
Mode
Special
data
registers
D8103
and
D8109
‐
D8199
are
allocated
to
the
modem
mode.
When
the
MicroSmart
starts
to
run,
D8109
and
D8110
store
the
default
values,
and
D8145
‐
D8169
store
the
default
initialization
string.
Originate
Mode
The
originate
mode
is
used
to
send
an
initialization
string
to
the
modem,
issue
the
ATZ
command
to
reset
the
modem,
and
dial
the
telephone
number.
To
execute
a
command,
turn
on
one
of
start
internal
relays
M8050
‐
M8052.
If
two
or
more
start
internal
relays
are
turned
on
simultaneously,
an
error
will
result
and
error
code
61
is
stored
in
modem
mode
status
data
register
D8111
(see
When
a
start
internal
relay
is
turned
on,
a
corresponding
sequence
of
com
‐
mands
is
executed
once
as
described
below.
When
the
start
command
fails,
the
same
command
is
repeated
as
many
as
the
retry
cycles
specified
by
D8109.
M8050:
Send
an
initialization
string,
send
the
ATZ
command,
and
dial
the
telephone
number
M8051:
Send
the
ATZ
command
and
dial
the
telephone
number
M8052:
Dial
the
telephone
number
Initialization
String
in
Originate
Mode
When
the
modem
mode
is
enabled
as
described
on
and
the
MicroSmart
is
started
to
run,
the
default
initializa
‐
tion
string
is
stored
to
data
registers
D8145
‐
D8169
at
the
END
processing
of
the
first
scan.
To
send
the
initialization
string
from
the
MicroSmart
to
the
modem,
turn
M8050
on;
then
the
ATZ
command
is
issued
and
the
telephone
number
is
dialed
successively.
Default
Initialization
String:
ATE0Q0V1&D2&C1\V0X4&K3\A0\N5S0=2&W
Data
Register
Stored
Data
Description
D8103
Online
Mode
Protocol
Selection
The
D8103
value
selects
the
protocol
for
the
RS232C
port
2
after
telephone
line
is
con
‐
nected.
0
(other
than
1):
Maintenance
protocol
1:
User
protocol
D8109
Retry
Cycles
(default
=
3)
The
D8109
value
selects
how
many
retries
will
be
made
until
the
operation
initiated
by
a
start
internal
relay
M8050
‐
M8056
is
completed.
0:
No
retry
1
‐
65535:
Executes
a
specified
number
of
retries
D8110
Retry
Interval
(default
=
90
sec)
The
D8110
value
specifies
the
interval
to
start
a
retry
of
dialing
when
a
dialing
fails
with
the
retry
cycles
set
to
a
value
more
than
1.
(Other
start
commands
are
repeated
contin
‐
uously
as
many
as
the
retry
cycles.)
Valid
value:
0
to
65535
(seconds)
If
a
telephone
line
is
not
connected
within
the
retry
interval,
the
MicroSmart
starts
a
retry.
Consequently,
if
the
retry
interval
is
set
to
a
too
small
value,
the
telephone
line
can
not
be
connected
correctly.
D8111
Modem
Mode
Status
Modem
mode
status
is
stored
(see
When
not
in
the
modem
mode,
D8111
stores
0.
D8115
‐
D8129
AT
Command
Result
Code
AT
command
result
codes
returned
from
modem
are
stored.
When
the
result
code
exceeds
30
bytes,
first
30
bytes
are
stored.
D8130
‐
D8144
AT
Command
String
AT
command
string
for
the
AT
general
command
mode
is
stored.
Enter
an
AT
command
string
to
these
data
registers
to
send
by
turning
on
M8054
(AT
command
start
internal
relay).
“AT”
and
LF
(0Ah)
are
appended
automatically.
D8145
‐
D8169
Initialization
String
Initialization
string
for
the
originate
and
answer
modes
is
stored.
To
change
the
initialization
string,
enter
a
new
value
to
these
data
registers.
The
new
value
is
sent
by
turning
on
M8050
or
M8055.
“AT”
and
LF
(0Ah)
are
appended
automat
‐
ically.
D8170
‐
D8199
Telephone
Number
Telephone
number
for
dialing
in
the
originate
mode
is
stored.
“ATD”
and
LF
(0Ah)
are
appended
automatically.
CR
LF
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...