
13:
P
ULSE
I
NSTRUCTIONS
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
13
‐
5
Special
Data
Registers
for
Pulse
Outputs
Three
additional
special
data
registers
store
the
current
frequency
of
pulse
outputs.
Timing
Chart
for
Enable
Pulse
Counting
This
program
demonstrates
a
timing
chart
of
the
PULS1
instruction
when
pulse
counting
is
enabled.
Device
Address
Function
Description
D8055
Current
Pulse
Frequency
of
PULS1
or
RAMP1
(Q0)
While
the
PULS1
or
RAMP1
instruction
is
executed,
D8055
stores
the
current
pulse
frequency
of
output
Q0.
The
value
is
updated
every
scan.
D8056
Current
Pulse
Frequency
of
PULS2
or
RAMP1
(Q1)
While
the
PULS2
or
RAMP1
(reversible
control
dual
‐
pulse
output)
instruction
is
executed,
D8056
stores
the
current
pulse
frequency
of
output
Q1.
The
value
is
updated
every
scan.
D8059
Current
Pulse
Frequency
of
PULS3
or
RAMP2
(Q2)
While
the
PULS3
or
RAMP2
instruction
is
executed,
D8059
stores
the
current
pulse
frequency
of
output
Q2.
The
value
is
updated
every
scan.
D1
M50
I0
PULS
1
S1
D200
D202
=
1
(enable
pulse
counting)
Output
Pulse
Q0
Output
Pulse
Frequency
D201
PV1
FR1
Start
Input
I0
• When
input
I0
is
turned
on,
PULS1
starts
to
generate
output
pulses
at
the
frequency
designated
by
the
value
stored
in
data
register
D201.
While
the
output
pulses
are
sent
out
from
output
Q0,
internal
relay
M50
remains
on.
• When
the
quantity
of
generated
output
pulses
reaches
the
preset
value
designated
by
data
registers
D203
and
D204,
PULS1
stops
generating
output
pulses.
Then
internal
relay
M50
turns
off,
and
internal
relay
M51
turns
on.
• If
the
output
pulse
frequency
value
in
D201
is
changed
while
generating
output
pulses,
the
change
takes
effect
in
the
next
scan.
When
changing
the
pulse
frequency,
make
sure
that
the
timing
of
the
change
is
much
slower
than
the
output
pulse
fre
‐
quency,
so
that
the
pulse
frequency
is
changed
successfully.
• If
input
I0
is
turned
off
before
reaching
the
preset
value,
PULS1
stops
generating
output
pulses
immediately,
then
internal
relay
M50
turns
off
and
internal
relay
M51
turns
on.
FR2
FR3
Preset
Value
D203
∙
D204
PV1
PV2
PV3
Pulse
Output
ON
M50
Pulse
Output
Complete
M51
PV2
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...