![IDEC MICROSmart FC5A Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/idec/microsmart-fc5a-series/microsmart-fc5a-series_user-manual_617369037.webp)
3:
M
OVE
I
NSTRUCTIONS
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
3
‐
11
Repeat
Operation
in
the
Indirect
Bit
Move
Instructions
Repeat
Bit
Devices
(Source
and
Destination)
If
a
repeat
operation
is
designated
for
bit
devices
such
as
input,
output,
internal
relay,
or
shift
register,
bit
devices
as
many
as
the
repeat
cycles
are
moved.
Repeat
Word
Devices
(Source
and
Destination)
If
a
repeat
operation
is
designated
for
word
devices
such
as
data
register,
bit
statuses
as
many
as
the
repeat
cycles
in
the
designated
data
register
are
moved.
S1
–
D10
I0
IBMV
S2
5
D1
–
D20
SOTU
REP
D2
12
D10
5
D20
+
12
Bit
15
Bit
5
Bit
12
Since
source
device
S1
is
a
data
register
and
the
value
of
source
device
S2
is
5,
the
source
data
is
bit
5
of
data
register
D10
designated
by
source
device
S1.
Since
destination
device
D1
is
a
data
register
and
the
value
of
source
device
D2
is
12,
the
destination
is
bit
12
of
data
register
D20
designated
by
destination
device
D1.
As
a
result,
when
input
I0
is
on,
the
ON/OFF
status
of
data
register
D10
bit
5
is
moved
to
data
register
D20
bit
12.
14 13 12
11 10 9
8
7
6
5
4
3
2
1
0
D10
Bit
15 14 13 12
11 10 9
8
7
6
5
4
3
2
1
0
D20
S1
R
M10
I1
IBMV
S2
5
D1
R
Q30
SOTU
REP
3
D2
9
M10
5
Q30
+
9
Repeat
=
3
M27
M10
M17
M20
M15
5th
from
M10
Q47
Q30
Q37
Q41
9th
from
Q30
Q44
Since
source
device
S1
is
internal
relay
M10
and
the
value
of
source
device
S2
is
5,
the
source
data
is
3
internal
relays
starting
with
M15.
Since
destination
device
D1
is
output
Q30
and
the
value
of
destination
device
D2
is
9,
the
destination
is
3
outputs
starting
with
Q41.
As
a
result,
when
input
I1
is
on,
the
ON/OFF
statuses
of
internal
relays
M15
through
M17
are
moved
to
outputs
Q41
through
Q43.
Q43
S1
R
D10
I2
IBMV
S2
5
D1
R
D20
SOTU
REP
3
D2
12
D10
5
D20
+
12
Repeat
=
3
Since
source
device
S1
is
data
register
D10
and
the
value
of
source
device
S2
is
5,
the
source
data
is
3
bits
starting
with
bit
5
of
data
regis
‐
ter
D10.
Since
destination
device
D1
is
data
register
D20
and
the
value
of
desti
‐
nation
device
D2
is
12,
the
destination
is
3
bits
starting
with
bit
12
of
data
register
D20.
As
a
result,
when
input
I2
is
on,
the
ON/OFF
statuses
of
data
register
D10
bits
5
through
7
are
moved
to
data
register
D20
bits
12
through
14.
Bit
15
Bit
5
Bit
12
14 13 12
11 10 9
8
7
6
5
4
3
2
1
0
D10
Bit
15 14 13 12
11 10 9
8
7
6
5
4
3
2
1
0
D20
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...