13:
P
ULSE
I
NSTRUCTIONS
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
13
‐
21
Timing
Chart
for
Reversible
Control
with
Single
Pulse
Output
This
program
demonstrates
a
timing
chart
of
the
RAMP1
instruction
when
reversible
control
is
enabled
with
single
pulse
output.
D1
M50
I0
RAMP
1
S1
D200
D204
=
1
(reversible
control
with
single
pulse
output)
• When
input
I0
is
turned
on,
RAMP1
generates
output
pulses
starting
at
the
initial
frequency
designated
by
the
value
stored
in
data
register
D202.
While
the
output
pulses
are
sent
out
from
output
Q0,
internal
relay
M50
remains
on.
• Operation
modes
0
through
2:
The
pulse
frequency
increases
according
to
the
frequency
change
rate
value
stored
in
data
register
D203.
• Operation
mode
3:
The
pulse
frequency
increases
as
long
as
the
frequency
change
time
stored
in
data
register
D203.
• While
the
output
pulse
frequency
is
on
the
increase,
internal
relay
M52
remains
on.
• Depending
on
the
control
direction
designated
by
the
value
stored
in
data
register
D205,
control
direction
output
Q1
turns
off
or
on
while
D205
stores
0
(forward)
or
1
(reverse),
respectively.
• When
the
output
pulse
frequency
reaches
the
steady
pulse
frequency
designated
by
the
value
stored
in
data
register
D201,
internal
relay
M52
turns
off.
When
the
output
pulse
frequency
starts
to
decrease,
internal
relay
M52
turns
on
again.
• When
the
quantity
of
generated
output
pulses
reaches
the
preset
value
designated
by
data
registers
D206
and
D207,
RAMP1
stops
generating
output
pulses.
Then
internal
relay
M50
and
M52
turn
off,
and
internal
relay
M51
turns
on.
• If
the
parameter
values
in
D200
through
D207
(except
for
D204)
are
changed
while
generating
output
pulses,
the
change
takes
effect
when
start
input
I0
is
turned
on
for
the
next
cycle.
• If
the
value
stored
in
D204
is
changed
after
start
input
I0
has
been
turned
on,
the
change
can
take
effect
only
after
the
CPU
starts
again.
• If
start
input
I0
is
turned
off
before
reaching
the
preset
value,
RAMP1
stops
generating
output
pulses
immediately,
then
internal
relay
M50
turns
off
and
internal
relay
M51
turns
on.
When
input
I0
is
turned
on
again,
RAMP1
restarts
to
generate
output
pulses
for
another
cycle,
starting
at
the
initial
pulse
frequency.
Pulse
Output
Status
M52
Output
Pulse
Q0
Start
Input
I0
Control
Direction
Output
Q1
Pulse
Output
Complete
M51
Initial
Pulse
Frequency
Steady
Pulse
Frequency
Control
Direction
D205
0
(Forward)
1
(Reverse)
Pulse
Output
ON
M50
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...