![IDEC MICROSmart FC5A Series Скачать руководство пользователя страница 274](http://html.mh-extra.com/html/idec/microsmart-fc5a-series/microsmart-fc5a-series_user-manual_617369274.webp)
24:
AS
‐
I
NTERFACE
M
ASTER
C
OMMUNICATION
24
‐
2
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
AS
‐
Interface
System
Requirements
Master
The
AS
‐
Interface
master
controls
and
monitors
the
status
of
slave
devices
connected
to
the
AS
‐
Interface
bus.
Normally,
the
AS
‐
Interface
master
is
connected
to
a
PLC
(sometimes
called
‘host’)
or
a
gateway.
For
example,
the
MicroSmart
AS
‐
Interface
master
module
is
connected
to
the
MicroSmart
CPU
module.
The
FC5A
MicroSmart
CPU
module
can
be
used
with
one
or
two
AS
‐
Interface
master
modules,
so
two
separate
AS
‐
Inter
‐
face
networks
can
be
set
up.
The
AS
‐
Interface
master
module
can
connect
a
maximum
of
62
digital
I/O
slaves.
A
maximum
of
seven
analog
I/O
slaves
can
also
be
connected
to
the
AS
‐
Interface
master
module
(compliant
with
AS
‐
Interface
ver.
2.1
and
analog
slave
profile
7.3).
Slaves
Various
types
of
slave
devices
can
be
connected
to
the
AS
‐
Interface
bus,
including
sensors,
actuators,
and
remote
I/O
devices.
Analog
slaves
can
also
be
connected
to
process
analog
data.
Slaves
are
available
in
standard
slaves
and
A/B
slaves.
Standard
slaves
have
an
address
of
1
trough
31
in
the
standard
address
range.
A/B
slaves
have
an
address
of
1A
through
31A
in
the
standard
address
range
or
1B
through
31B
in
the
expanded
address
range.
Among
the
A/B
slaves,
slaves
with
an
address
of
1A
through
31A
are
called
A
slaves,
and
slaves
with
an
address
of
1B
through
31B
are
called
B
slaves.
The
AS
‐
Interface
master
module
cannot
be
connected
to
the
all
‐
in
‐
one
10
‐
I/O
and
16
‐
I/O
type
CPU
modules
and
the
expansion
interface
module.
One
or
two
AS
‐
Interface
master
modules
can
be
connected
to
the
CPU
module.
If
more
than
two
AS
‐
Interface
master
modules
are
connected,
an
error
occurs
and
special
data
register
D8037
(quantity
of
expansion
I/O
modules)
stores
error
code
40
(hex).
Normally,
a
maximum
of
four
expansion
I/O
modules
can
be
connected
to
the
all
‐
in
‐
one
24
‐
I/O
type
CPU
module.
But
when
one
or
two
AS
‐
Interface
master
modules
are
connected,
only
a
total
of
three
expansion
modules
can
be
connected,
including
the
AS
‐
Interface
master
modules.
Do
not
connect
more
than
three
expansion
modules
due
to
the
amount
of
heat
generated.
If
more
than
three
expansion
modules,
including
the
AS
‐
Interface
master
module,
are
connected,
an
error
occurs
and
special
data
register
D8037
(quantity
of
expansion
I/O
modules)
stores
error
code
20
(hex).
Similarly,
slim
type
CPU
modules
can
normally
connect
a
maximum
of
seven
expansion
I/O
mod
‐
ules,
but
can
connect
a
maximum
of
six
expansion
modules
including
one
or
two
AS
‐
Interface
mas
‐
ter
modules.
If
more
than
six
expansion
modules,
including
the
AS
‐
Interface
master
module,
are
connected,
an
error
occurs
and
special
data
register
D8037
(quantity
of
expansion
I/O
modules)
stores
error
code
20
(hex).
The
AS
‐
Interface
master
module
can
connect
a
maximum
of
seven
analog
I/O
slaves.
When
more
than
seven
analog
I/O
slaves
are
connected,
the
AS
‐
Interface
system
will
not
operate
correctly.
AS
‐
Interface
Master
Module
FC4A
‐
AS62M
One
or
two
AS
‐
Interface
master
modules
can
be
mounted.
Note:
The
AS
‐
Interface
master
module
can
not
be
mounted
to
the
right
of
the
expansion
inter
‐
face
module.
Applicable
FC5A
MicroSmart
CPU
Modules
FC5A
‐
C24R2
FC5A
‐
C24R2C
FC5A
‐
D16RK1
FC5A
‐
D16RS1
FC5A
‐
D32K3
FC5A
‐
D32S3
FC5A
‐
D12K1E
FC5A
‐
D12S1E
Note:
FC5A
‐
C24R2D
cannot
use
the
AS
‐
Interface
master
module.
Caution
Содержание MICROSmart FC5A Series
Страница 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Страница 2: ......
Страница 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Страница 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Страница 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...