vogue combination boiler -
Installation and Servicing
81 FAULT FINDINg C hART MAIN MENU
Overheat Lockout
Fill System to 1 Bar
Bleed Radiators, Refill System
Check Radiator Valves are Open
Reset Boiler by pressing r
Flow/Return Reversed
Contact Installer
Ignition Lockout
Check other Gas Appliances work
If not, re-instate gas supply
Reset Boiler by pressing r
If fault persists contact installer
Flame Loss
Check other gas appliances work. If
not, re-instate gas supply.
If fault persists, contact installer
No Water Flow Fault
Fill System to 1 Bar
Bleed Radiators, Refill System
If Fault persists contact installer
Thermal Fuse Lockout
Reset Boiler
If fault persists contact installer
PCB Replaced
Reset boiler by pressing r
Pump Rotor Blocked
If fault persists contact installer
No Connection to Primary PCB
Turn power off and on
Contact Installer
Too Many Resets
Contact Installer
Flame on before Gas Valve on
Contact Installer
Flow Thermistor Fault
Contact Installer
Outside Sensor Fault
Contact Installer
Return Thermistor Fault
Contact Installer
Fan Fault
Contact Installer
PCB Replaced Incorrectly
Contact Installer
Low Water Pressure
Fill System to 1 Bar
Bleed Radiators
Refill System to 1 Bar
Low Mains Voltage
NO CH BUT DHW OK
NO DHW BUT CH OK
BLANK DISPLAY
FLOW TEMPERATURE
SETPOINT CANNOT BE
INCREASED TO 80ºC
PUMP RUNS DURING
THE NIGHT
Go to Frame 94
No CH but DHW OK
Go to Frame 95
No DHW but CH OK
Go to Frame 96
Blank Display
Ensure Flow Temperature
is not limited within Installer
Mode
(see Frame 37)
Ensure System Frost
Protection Temperature
Setpoint is not set too high
(see Frame 40)
Go to Frame 82
Overheat Lockout
Check if Flow
Thermistor correctly
clipped to pipe
Replace Flow
Thermistor
Go to Frame 83
Ignition Lockout
Go to Frame 84
Flame Loss
Go to Frame 92
No Water Flow Fault
Go to Frame 85
Flame Loss
Reset boiler by
pressing r
Unblock Pump
Go to Frame 93
No Connection to
Primary PCB
5 Resets within 15
minutes
Turn power off and on
Go to Frame 86
Flame On before Gas
Valve On
Go to Frame 87
Flow Thermistor Fault
Go to Frame 88
Outside Sensor Fault
Go to Frame 89
Return Thermistor
Fault
Go to Frame 90
Fan Fault
Ensure BCC fitted
correctly
Ensure correct BCC
fitted
Go to Frame 91
Low Water Pressure
Less than 160V to boiler
Check voltage at boiler
mains in
Check if local generator 10V
Contact Electricity Provider
Содержание Vogue Combi c26
Страница 2: ...2 vogue combination boiler Installation and Servicing ...
Страница 68: ......
Страница 74: ...74 NOTEs vogue combination boiler Installation and Servicing ...
Страница 75: ...75 NOTEs vogue combination boiler Installation and Servicing ...