10
vogue combination boiler -
Installation and Servicing
gENERAL
51 37.5
65
67
67
65
50
42.5
445
450
330
2.5
2.5
from case
740
Side flue
dim. A
Cond. Drain
CH Flow
DHW Outlet
DHW Inlet
CH Return
PR
V Outlet
Gas Inlet
1
BOILER DIMENsIONs, sERVICEs & CLEARANCEs
all dimensions in mm
The boiler connections are made on the boiler connection tails.
Refer to Frame 24.
The following minimum clearances must be maintained for
operation and servicing.
Additional space will be required for installation, depending
upon site conditions.
side and Rear Flue
a.
Provided that the flue hole is cut accurately, e.g. with a core
drill, the flue can be installed from inside the building where
Front clearance
The minimum front clearance when built in to a cupboard is
5mm from the cupboard door but 450mm overall clearance
is still required, with the cupboard door open, to allow for
servicing.
*
Bottom clearance
Bottom clearance after installation can be reduced to 5mm.
This must be obtained with an easily removable panel, to
enable the consumer to access the filling loop, and to provide
the 100mm clearance required for servicing..
wall thicknesses do not exceed 600mm (24”). Where the
space into which the boiler is going to be installed is less
than the length of flue required the flue must be fitted from
the outside.
Installation from inside ONLy
b. If a core boring tool is to be used inside the building the
space in which the boiler is to be installed must be at least
wide enough to accommodate the tool.
Содержание Vogue Combi c26
Страница 2: ...2 vogue combination boiler Installation and Servicing ...
Страница 68: ......
Страница 74: ...74 NOTEs vogue combination boiler Installation and Servicing ...
Страница 75: ...75 NOTEs vogue combination boiler Installation and Servicing ...