background image

30

Concord CXA/H 

- Installation and Servicing

SHORT LIST OF PARTS

Key No.

Description

Qty.

 Product No.

12.4

Boiler body insulation ............................... CXA  40/H

1

150  093

.................................................................. CXA 50/60/H

1

150  094

.................................................................. CXA 70/80/H

1

150  095

.................................................................. CXA 90/100/H

1

150  096

.................................................................. CXA 110/120/H

1

154  856

23

LH main burner ......................................... Worgas 0.087.751 CXA 40/H

1

150  153

.................................................................. Worgas 0.087.753 CXA 50/60/H

1

150 154

.................................................................. Worgas 0.087.755 CXA 70/80/H

1

150 155

.................................................................. Worgas 0.087.757 CXA 90/100/H

1

150 156

.................................................................. Worgas  0.087.761  CXA 110/120/H

1

154 812

24

Centre & RH main burners ....................... Worgas 0.087.750 CXA 40/H

2

150  149

.................................................................. Worgas 0.087.752 CXA 50/60/H

2

150 150

.................................................................. Worgas 0.087.754 CXA 70/80/H

2

150 151

.................................................................. Worgas 0.087.756 CXA 90/100/H

2

150 152

.................................................................. Worgas 0.087.760 CXA 110/120/H

2

154 811

26

Main  burner  injectors ................................ Size 3.4 mm; CXA 40/H

3

111  323

.................................................................. Size 3.82mm; CXA 50/H

3

111  324

.................................................................. Size 4.12mm; CXA 60/H

3

111  325

.................................................................. Size 4.57mm; CXA 70/H

3

111  326

.................................................................. Size

 

4.86mm; CXA 80/H

3

013  177

.................................................................. Size 5.2mm; CXA 90/H

3

111  328

.................................................................. Size

 

5.3mm; CXA 100/H

3

013  179

.................................................................. Size

 

5.5mm; CXA 110/H

3

157  904

.................................................................. Size

 

5.6mm; CXA 120/H

3

154  840

27

Pilot burner  - HONEYWELL Q 349 A1067 complete with injector

1

077 105

28

Pilot burner injector - HONEYWELL 45900421-011

1

004 545

29

Gas control valve - HONEYWELL V4601 AB 1034

1

154  810

.

Gas control valve - HONEYWELL VR4605 AB 1019 CXA 90 - 120/H

1

111  869

Gas valve plugs and lead assy. CXA 40 -120/H

1

154 733

Gas valve plugs and lead assy. CXA 90 -120/H

1

112 431

Gas valve plugs and lead assy. CXA 90 -120/H

1

139 269

32

Ignition electrode and H.T. lead assy. ......

1

154 967

33

Flame sensing electrode .........................

1

154 818

Boiler status neons .................................. Burner on

1

154 854

.................................................................. Overheat

1

154 855

.................................................................. Lockout

1

154 855

37

Electronic thermostat sensor & lead assembly

1

154 816

38

Thermostat potentiometer assembly .......

1

154 850

39

Thermostat knob .......................................

1

170 859

40

Overheat thermostat .................................

1

155 791

41

Control box assembly, complete ..............

1

157 152

42

Printed circuit board S4561B1054 ...........

1

154 813

43

Printed circuit board  W4115A1020 ..........

1

154 815

When ordering spare parts please quote:

1.

Boiler model

2.

Boiler serial no. (refer to the data plate on the combustion chamber)

3.

Boiler B.G. P.I. No. (refer to the data plate on the combustion chamber)

4.

Description

5.

Quantity

6.

Product no.

The following are parts commonly
required as replacements, due to
damage or expendability.

Their failure or absence is likely to affect
the safety and/or performance of this
appliance.

Содержание Concord CXA 40/H

Страница 1: ......

Страница 2: ...1078 Water content litre 22 30 30 37 37 45 45 53 53 gal 4 8 6 6 6 6 8 2 8 2 9 9 9 9 11 7 11 7 Table 2 General Data This value is in the UK government s Standard Assessment Procedure SAP for energy ra...

Страница 3: ...he law is complied with The Concord CXA 40 H 120 H range of boilers has been tested and certified by British Gas to prEN656 for use with Natural gas only Multiple boiler installations The Concord CXA...

Страница 4: ...is designed to protect the boiler and may not necessarily protect the remote parts of the system OPTION KITS Remote indication kit This kit gives the facility of remote indication of the boiler statu...

Страница 5: ...rrun litres Relationship between load and water volume for the minimum capacity of water circuit during the 6 minute pump overrun period for different boiler outputs Graph 1 Heat Load Water Volume CXA...

Страница 6: ...into the expansion cistern must be avoided The above circuit capacity during pump overrun may be achieved either by provision of an adequate bypass circuit or by ensuring that a zone of suitable size...

Страница 7: ...2 BS 6281 Part 1 BS 6282 Part 1 BS 6283 Part 4 Working pressure 6 bar maximum Particular reference should be made to BS 6644 Section 6 and Guidance note PM5 Automatically controlled steam and hot wate...

Страница 8: ...less steel rigid or flexible flue liner grade 304 316 may be used in conjunction with a 50 mm minimum thick layer of vemiculite or perlite granules between the liner and the inner skin of the chimney...

Страница 9: ...ssembled boiler body with distributor tube on a wooden pallet base enclosed in a wooden crate 2 Carton containing the casing fastenings and flue brush 3 Carton containing the installation pack and ins...

Страница 10: ...and the flow tapping d Complete the water connections by plugging the 2 front top tappings with the 2 BSP plugs provided 1 Fit the distributor tube supplied with the boiler into one of the return conn...

Страница 11: ...stat phial and control sensor are correctly secured in the pockets Refer to Frame 13 9 SYSTEM CONNECTIONS One flow and return connection should be made to the rear of the boiler either on one side or...

Страница 12: ...stat pocket adjacent to the flow connection Fit the plastic Heyco bush over the sensor lead at the line shown and insert it into the thermostat pocket Ensure that the Heyco bush is correctly located 1...

Страница 13: ...unswitched live supply which the boiler requires to allow the pump overrun facility to operate should be controlled by the above switched fused supply but should connect from there directly to the boi...

Страница 14: ...14 Concord CXA H Installation and Servicing INSTALLATION 16 INTERNAL WIRING br brown r red LEGEND b blue bk black y yellow w white y g yellow green or orange v violet pk pink INSTALLATION...

Страница 15: ...any zone may be the load during overrun all zones MUST individually be able to satisfy the conditions in the foregoing paragraph If not all zones can do this then consider other means of control deta...

Страница 16: ...now calls for heat its thermostat will open Zone 1 valve via the normally open contacts of the relay IMPORTANT Terminal L2 may control the appropriate pump s directly provided that the total running...

Страница 17: ...2 minutes Any leaks must be cured Replace all pressure test point screws 21 INITIAL LIGHTING 1 Check that the boiler thermostat knob on the control box is OFF 2 Ensure that the main gas inlet cock is...

Страница 18: ...ectly to manual on off operations of any controls fitted in the gas control circuit Check in the following manner the operation of the flame failure safety device 1 Extinguish the main burner and pilo...

Страница 19: ...door lift it and carefully drop it down Pull off the flame detector lead and the spark electrode lead connections from the S4561B1054 PCB the left hand board Undo the strain relief clamp and feed the...

Страница 20: ...on the inside of the casing front panel and check the gas connections for tightness as detailed under Testing for Gas Soundness Frame 20 Check gas pressures and the gas rate test as instructed in Fra...

Страница 21: ...Frame 27 2 Both RH and centre burners can be removed by sliding each one back to clear the injector and then lifting out 3 To exchange the LH burner remove it from the boiler as previously described...

Страница 22: ...35 BURNER AND CONTROLS ASSEMBLY Exploded View CXA 40 H 80 H 36 BURNER AND CONTROLS ASSEMBLY Exploded View CXA 90 H 120 H LEGEND 1 Main gas inlet cock 2 Gas inlet union 3 Gas control valves 4 O ring s...

Страница 23: ...uit board and release cable clamp from the back panel 5 Pull the sensor lead through the grommeted hole in the back panel and the wire clips 6 Fit the new sensor and reassemble in reverse order ensuri...

Страница 24: ...he lower front panel 2 Undo the 2 screws securing the control box front panel Carefully lift it up and lower down 3 Pull off the 2 plugs and 3 push on connections from the board The board can now be r...

Страница 25: ...e part Gloves supplied with the spare part 1 Damp down the combustion chamber area containing the insulation boards 2 Remove the insulation boards The replacement boards are supplied in a plastic bag...

Страница 26: ...remove the left hand burner the pilot gas pipe connection at the gas valve must be removed 4 The left hand burner may now be removed by pushing it back to clear the injector and lifting it out taking...

Страница 27: ...bly are not fixed together therefore CARE MUST BE TAKEN TO PREVENT the installed section coming apart 8 Repeat the above procedure for all of the remaining sections until the assembly is complete 9 Fi...

Страница 28: ...sk which has required the breaking and remaking of electrical connections the following checks MUST be repeated Check that the gap between the electrode and pilot burner is 3 4 mm Ensure that the H T...

Страница 29: ...OES OUT ON OVERHEAT THERMOSTAT Are the thermostat sensors in their correct pockets YES Is there an unswitched live supply to terminal L1 on the plug in terminal connection at the control box Is the pu...

Страница 30: ...ctor 1 077 105 28 Pilot burner injector HONEYWELL 45900421 011 1 004 545 29 Gas control valve HONEYWELL V4601 AB 1034 1 154 810 Gas control valve HONEYWELL VR4605 AB 1019 CXA 90 120 H 1 111 869 Gas va...

Страница 31: ...2 CXA 80 H 1 111 652 CXA 90 100 H 1 111 653 CXA 110 120 H 1 154 898 50 Casing top panel white stove enamel CXA 40 H 1 111 293 CXA 50 H 1 111 294 CXA 60 H 1 111 295 CXA 70 H 1 111 296 CXA 80 H 1 111 29...

Страница 32: ...inuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice The Ideal Boilers Technical Training Centre offers a series of fir...

Отзывы: