![IDEAL INDUSTRIES SignalTEK II Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/ideal-industries/signaltek-ii/signaltek-ii_user-manual_617117042.webp)
156810 Iss 1
SignalTEK II
Page 42
User Guide
Link-Remote Performance Tests
(continued)
VoIP Performance Test
Results
Test conditions
Line Rate
10 Mb/s
100 Mb/s
1000 Mb/s
Information Rate Mb/s
Duplex
Full
Half
Frame Size
Frame Fill
Overall result
Pass (100% frames transmitted and Failure threshold not exceeded)
Fail
Transmitted Frames
Count (0 to 10
12
)
Percentage (0 to 100% with colored bar indication - Green if 100%, red if
<100%)
Result
Pass (100%)
Fail (<100%)
Received Frames
Count (0 to 10
12
)
Percentage (0 to 100%)
Errored Frames
Count (0 to 10
12
)
Percentage (0 to 100% with colored bar indication -, Green if 100%, red if
<100%)
Result
Pass (100%)
Fail (>100%))
Web Performance Test
Fixed Settings
Frame size
Fixed 1518 bytes
Frame Fill
Random
Setup
Number of Simultaneous Sessions
User-defined. (Range 1 to 500. Default 10)
Equivalent Information Rate calculated and displayed
IR = 1.8 x No of sessions (Mb/s)
Equivalent Frame Rate calculated but not displayed
FR = IR / 1518 / 8 (fps)
Duration
User-defined (hh:mm:ss upto 24 hours. Default 10 secs)
Failure Threshold
Number of frames (0 to 99. Default 0)