![IDEAL INDUSTRIES SignalTEK II Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/ideal-industries/signaltek-ii/signaltek-ii_user-manual_617117040.webp)
156810 Iss 1
SignalTEK II
Page 40
User Guide
Cable Tests
(continued)
Tone Generator
Setup
Tones - 3
Wire I/D - Tone applied to one of 8 pins relative to the other 7
- Tone applied across one of 4 pairs
Test
Audible tone detected using compatible tone probe
Cable Performance Test
Setup
IEEE802.3
Tick-box
Ticked
Fix Failure Threshold at 0
Fix Duration at 10 secs
Unticked
Allow editing of Threshold and Duration
Frame size
Fixed 1518 bytes
Frame Fill
Fixed
Duration
User-defined (hh:mm:ss up to 24 hours. Default 10 secs)
Failure Threshold
Number of frames (0 to 9999. Default 0)
Test
- Back-to back frames transmitted to Remote for specified duration.
- Remote loops frames back
- Received frames checked and counted
Results
Test conditions
Line Rate
10 Mb/s
100 Mb/s
1000 Mb/s
Duplex
Full
Half
Frame Size
Frame Fill
Overall result
Pass (100% frames transmitted, 100% frames received and Failure
threshold not exceeded)
Fail
Transmitted Frames
Count (0 to 10
12
)
Percentage (0 to 100% with colored bar indication - green if 100%, red if
<100%)
Result
Pass (100%)
Fail (<100%)
(continued)
www.vemco.pl
Содержание SignalTEK II
Страница 1: ...SignalTEK II User Guide 156810 issue 1 w w w v e m c o p l ...
Страница 56: ...w w w v e m c o p l ...
Страница 57: ...w w w v e m c o p l ...
Страница 58: ...A subsidiary of IDEAL INDUSTRIES INC w w w v e m c o p l ...