![IDEAL INDUSTRIES SignalTEK II Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/ideal-industries/signaltek-ii/signaltek-ii_user-manual_617117016.webp)
156810 Iss 1
SignalTEK II
Page 16
User Guide
IP Tests continued
Set the target URL/Numerical address (select from up to 10 targets stored in the v6
TARGET look up table or edit the currently displayed URL),
Count (Number of times to repeat the Ping - 1 to 999999),
Pause (Interval between successive Pings - 1 to 5 seconds),
Length (Number of bytes in the Ping frame payload - 8 to 1000 bytes).
Set the target URL/Numerical address (select from up to 10 targets stored in the v6
TARGET look up table or edit the currently displayed URL),
Maximum number of hops (1 to 30),
Timeout (Abort timeout for any hop - 2 to 30 secs),
Select Name Lookup if supported by your network. If not required, de-select Name
Lookup to reduce test time.
The five performance tests that follow are available:
Tick IEEE802.3 check box to set the frame failure threshold to 0 and the test duration to
10 secs. With the tick box unchecked the frame failure threshold and duration can be set
manually to suit your test. The frame size is permanently set to 1518. Frame fill is
always fixed.
No. of Calls (Set expected number of simultaneous calls on the network
– 1 to 10,000),
Threshold (Frames) (Enter the number of errored frames acceptable
– 0 to 99),
Duration (Set test duration from 1 second up to 24 hrs).
No. of sessions (Set expected number of simultaneous sessions on the network
– 1 to
500),
Threshold (Frames) (Enter the number of errored frames acceptable
– 0 to 99),
Duration (Set test duration from 1 second up to 24 hrs).
Definition (Set to HD or SD),
No. of Streams (Set expected number of simultaneous calls on the network
– 1 to 70),
Threshold (Frames) (Enter the number of errored frames acceptable
– 0 to 99),
Duration (Set test duration from 1 second up to 24 hrs).
Resolution (Set to VGA, 720p, 1080p, 3MP or 5MP),
CODEC (Set to H.264 or MJPEG),
No. of Cameras (Set the number of cameras in the system),
Threshold (Frames) (Enter the number of errored frames acceptable
– 0 to 99).
Select the tests that will run every time the Near-End or Remote Unit
’s Autotest button is
pressed. For details of the tests available, see Fig 34.
Select this option to enter up to 10 IPv4 targets in a look up table. The targets you save
here can be quickly selected when running Ping4 and TRoute4 tests.
Select this option to enter up to 10 IPv6 targets in a look up table. The targets you save
here can be quickly selected when running Ping6 and TRoute6 tests.