Appendix D
Model Features, Options, Accessories, and Specifications
D-3
Environmental and Physical Specifications
The following environmental specifications apply to all LANTEK Cable Testers.
LANTEK 6 Specifications
Range
Resolution
Accuracy
Length (50 0r 100
Ω
Cable)
0-2000 ft
1 ft
+(3% + 3 ft)
Delay
0-8000 ns
1 ns
+(3% + 1 ns)
Average Impedance
35-180
Ω
0.1
Ω
+(3% + 1
Ω
)
Capacitance (Bulk)
0-100 nF
1 pF or 3 dig
+(2% + 20 pF)
Capacitance
0-100pF/ft
0.1 pF
+(2% + 1 pF)
DC Loop Resistance
0-200
Ω
0.1
Ω
+(1% + 2
Ω
)
Attenuation
1-350 MHz
0.1 dB
Level III*
NEXT
1-350 MHz
0.1 dB
Level III*
Return Loss
1-350 MHz
0.1 dB
Level III*
ELFEXT
1-350 MHz
0.1 dB
Level III*
Noise Floor
>-90 dB
Dynamic Range
< 90 dB
* Level III only specified to 250 MHz
Storage Capacity (Internal Memory)
Cat 5e, 6 (No Graphics)
6,000 Test Results
Cat 5e with Graphics
100 Test Results
Cat 6 with Graphics
60 Test Results
Storage Capacity (External 32MB Flash)
Cat 5e, 6 (No Graphics)
24,000 Test Results
Cat 5e with Graphics
400 Test Results
Cat 6 with Graphics
240 Test Results
Содержание LANTEK
Страница 1: ...IDEAL INDUSTRIES LANTEK CABLE TESTERS USER S GUIDE 01 FEBUARY 2002 MANUAL PART 6510 00 5000 REV A ...
Страница 80: ...Chapter 3 Calibration Configuration and Special Operations 3 39 store up to 10 custom cables ...
Страница 116: ...Chapter 4 Autotesting 4 24 ...
Страница 124: ...Chapter 5 Analyze Testing 5 8 ...
Страница 172: ...Chapter 6 Using LANTEK REPORTER 6 48 ...
Страница 208: ...Appendix A Safety Precautions A 4 ...