Chapter 3
Calibration, Configuration, and Special Operations
3-13
Setting Autotest Preferences
Autotest can be set to automatically stop on the first failed test, as well as to print,
save, and name test results at the completion of each test series.
Table 3-4: Autotest Preference Options
Option
Action
Simple Cable ID
Assigns a fixed alpha value for the Cable ID.
Pass/Fail Icon
Display Pass or Fail icon for overall test and individual test.
Stop on Fail
Autotest aborts at the first failed test. Otherwise, Autotest continues
until all tests are completed, regardless of results.
Note: If a wire map cannot be reliably completed due to gross
miswiring, the Autotest may abort regardless of the setting of
this preference.
AutoSave
Autotest automatically names and saves any passed Autotest results.
Failed tests are
not
automatically saved.
Save Graphs
Displaying graphs on the DH requires data to be transferred from
the RH to the DH. To save time during testing, do not select this
option.
Auto Increment
Autotest automatically increments the Single and Double Cable ID
test counters.
Marginal
Pass/Fail
Display Pass or Fail with an * identifying marginally effected test(s).
ACR
Perform ACR Test.
Resistance
Perform Resistance Test.
Impedance
Perform Impedance Test.
Enable 24
ELFEXT
Enable measurements at the DH for all possible pair combinations.
Содержание LANTEK
Страница 1: ...IDEAL INDUSTRIES LANTEK CABLE TESTERS USER S GUIDE 01 FEBUARY 2002 MANUAL PART 6510 00 5000 REV A ...
Страница 80: ...Chapter 3 Calibration Configuration and Special Operations 3 39 store up to 10 custom cables ...
Страница 116: ...Chapter 4 Autotesting 4 24 ...
Страница 124: ...Chapter 5 Analyze Testing 5 8 ...
Страница 172: ...Chapter 6 Using LANTEK REPORTER 6 48 ...