Chapter 3
Calibration, Configuration, and Special Operations
3-8
Tester Field Calibration
It is recommended that the LANTEK tester be calibrated every 7 days. A
calibration reminder message will appear on the Display Handset screen when
calibration is requested.
The purpose of calibration is to (1) synchronize the units, (2) qualify (test) the
patchcords and (3) gather loss data regarding the patchcords and mated
connections.
To calibrate the tester, perform the following steps:
1.
Connect the channel adapters to the Display Handset and Remote Handset.
2.
Power both units on.
3.
Connect one of the two appropriate patchcords to the adapters of the DH and
RH units.
Figure 3-3: Tester Field Calibration Setup