Chapter 3
Calibration, Configuration, and Special Operations
3-10
If calibration is unsuccessful, the tester will briefly display either a Warning screen
displaying “No Remote Handset”or a Calibration Failure screen.
The display handset will return to the Ready screen upon exiting from a calibration
error screen.
Note: If the field calibration is out of date, you can still perform an autotest but the results
may not be qualified or reliable.
Table 3-3: Unsuccessful Field Calibration Checklist
Action
Result
Check the battery power on
both the Display and Remote
Handsets.
Check the DH for a low battery message.
If the Display Handset indicates a low battery, you must
recharge the battery before the unit will pass calibration.
The RH will not respond if its battery is low.
Check the adapter and
connections.
Make sure the adapter is correctly seated and there are
no bent pins.
If you are unable to successfully calibrate the tester, contact your local distributor
or an IDEAL INDUSTRIES service facility for assistance.
Содержание LANTEK
Страница 1: ...IDEAL INDUSTRIES LANTEK CABLE TESTERS USER S GUIDE 01 FEBUARY 2002 MANUAL PART 6510 00 5000 REV A ...
Страница 80: ...Chapter 3 Calibration Configuration and Special Operations 3 39 store up to 10 custom cables ...
Страница 116: ...Chapter 4 Autotesting 4 24 ...
Страница 124: ...Chapter 5 Analyze Testing 5 8 ...
Страница 172: ...Chapter 6 Using LANTEK REPORTER 6 48 ...
Страница 208: ...Appendix A Safety Precautions A 4 ...