Appendix C
Measurement Methods and Limits
C-8
EINBETTENEINBETTENEINBETTENEINBETTENPower Sum
ACR (ANSI/TIA/EIA)
ANSI/TIA/EIA
Frequency
(MHz/dB)
Permanent Channel Permanent Channel Permanent Channel Permanent Channel
1.00
54.90
54.80
71.20
70.30
2.00
-
-
3.00
-
-
4.00
48.00
46.40
61.80
60.50
8.00
41.40
39.40
57.00
55.60
10.00
39.30
37.00
55.50
54.00
16.00
34.00
31.50
52.20
50.60
20.00
31.50
28.80
50.70
49.00
25.00
28.80
25.90
49.10
47.30
31.25
26.00
22.80
47.50
45.70
62.50
15.90
12.00
42.70
40.60
100.00
7.70
3.10
39.30
37.10
125.00
37.70
35.40
155.52
36.10
33.80
175.00
35.30
32.90
200.00
34.30
31.90
250.00
32.70
30.20
Category 3
Category 5
Category 5e
Category 6 (Draft 9)
ANSI/TIA/EIA568/TSB67
ANSI/TIA/EIA568/TSB67/95 ANSI/TIA/EIA568/TSB67/95
ANSI/TIA/EIA568