Chapter 2
Your Cable Tester
2-18
Operational Sequence
•
The DH searches for the RH.
•
During
testing
, if the two handsets are unable to communicate, the DH will
display a message that it is searching for the RH and continue trying to
establish communications until you manually cancel the operation or the RH
is found. If the handsets are unable to establish communication, check the
links to verify proper connection.
•
During
field calibration
, if the two handsets are unable to communicate, the
DH will display a message instructing you to connect the DH and RH together
using the adapters and reference patchcords. If you attempt to run the test
without the adapter, the DH will display a warning message.
Battery and Power Management
Both the Display and Remote Handsets use interchangeable rechargeable NiMH
(Nickel Metal-Hydride) battery packs.
•
The DH (Display Handset) can be run on battery power for approximately
eight hours. Actual battery power times will vary based on factors such as
operating time versus standby time, use of the display backlight, and
temperature.
•
When the battery is almost empty, the tester displays a warning message. The
tester will automatically shut down before testing results are affected.
•
The RH (Remote Handset) can be run on battery power for approximately
eight hours.
•
After a brief period of inactivity, the DH and RH automatically power down
to save battery power.
Содержание LANTEK
Страница 1: ...IDEAL INDUSTRIES LANTEK CABLE TESTERS USER S GUIDE 01 FEBUARY 2002 MANUAL PART 6510 00 5000 REV A ...
Страница 80: ...Chapter 3 Calibration Configuration and Special Operations 3 39 store up to 10 custom cables ...
Страница 116: ...Chapter 4 Autotesting 4 24 ...
Страница 124: ...Chapter 5 Analyze Testing 5 8 ...
Страница 172: ...Chapter 6 Using LANTEK REPORTER 6 48 ...
Страница 208: ...Appendix A Safety Precautions A 4 ...