8
3.4.6
Menu - Configuration
All menus and setting will now be available
for that particular access level. There will
now also be the chance to reconfigure
different functions within the system:
Configuration
General
Recommission system
Recommission Plant
Configuration
General
Recommission System
Recommission Plant
Recommission Boiler
Configuration
Recommission System
Recommission Plant
Recommission Boiler
Recommission HC
Configuration
Recommission Plant
Recommission Boiler
Recommission HC
Recommission DHW
Configuration
Recommission Boiler
Recommission HC
Recommission DHW
Fault Management
Configuration
Recommission HC
Recommission DHW
Fault management
Configuration
Recommission DHW
Fault management
Depending upon the access level, not all
configuration options will be available.
Once selected, refer to the Configuration
section below for guidance.
3.4.6.1 Fault Management
The management section relates to the
installed system tools rather than the boiler
or accessories. It allows for the ability to set
up real time datalogging of system variables
in order to allow specific site related issues
to be identified and system adjustments to
be made to optimise the performance of the
iCCS system.
It also allows for the backup configuration
file to be updated as a maintenance function
when a recommission step has been carried
out causing a change in any of the functional
modules in the system, Plant, Boiler, HC,
DHW. A full recommission system always
offers a backup.
Backup is only possible in boiler cascades
of 2 or more boilers where a slave system
manager is available.
Fault management
Logging
Store backup on dev. no.
Fault management
Logging
Store backup on dev. no.
3.4.6.1.1 Data Logging
Data logging can be activated and de-
activated. The logging data file can also be
cleared. It is a First-In First-Out file with a
fixed logging interval of 5 minutes.
The data file can then be downloaded
using the VariSoft utility to a Windows
Personal Computer for analysis as a Comma
Separated Variable (.CSV) file Type.
Logging
Enable
Reset
Logging can be enabled by setting a flag
using the select key, a tick will then appear
in the box showing that logging has been
enabled.
Enable
On/Off
Done
Enable
On/Off
Done
Once a logging period has been completed
the enable can be reset in the same way,
then the data downloaded, and the store
cleared.
Logging
Enable
Reset
3.4.6.1.2 Backup Storage, Post
Configuration
A backup of all configuration parameters in
a cascade to one or more nominated slave
boilers (System managers) can be made
post configuration to reflect any changes
made.
This allows the system to be restored easily
to the original or final saved configuration
at any point, particularly if a master boiler
system manager has had to be replaced.
Store backup on dev. no.
2
Done
Store backup on dev. no.
2
Done