98
G. Using LINUX
After having explained the installation of the ICP Controller and the host drives in chapters
B and C, we now explain how to install the operating system LINUX. For a successful in-
stallation, we recommend that you take a close look at the manuals which came with your
LINUX distribution package. We have tested LINUX from: Caldera, Debian, DLD, LST, Red-
Hat and S.u.S.E. . If you require an ICP Linux disk, this can be created from the ICP System
CDROM.
G.1 Transparency of Host Drives
The structure of the Host Drives, which have been installed with ICPCON (in chapter C), is
not known to LINUX. I.e., the operating system does not recognize that a given Host Drive
consists of a number of hard disks forming a disk array. To LINUX, this Host Drive simply
appears as one single hard disk with the capacity of the disk array. This complete transpar-
ency represents the easiest way to operate disk arrays under LINUX; neither LINUX nor the
PCI computer need to be involved in the administration of these complex disk array con-
figurations.
G.2 Available Drivers and Tools
gdth.tgz
ICP driver sources for intel and alpha systems
icpcon.tgz
ICPCON and object files (intel)
icpcona.tgz
ICPCON and object files (alpha)
The following ICP drivers are part of the various Kernel versions:
from Kernel 2.0.31
ICP driver 1.00
from Kernel 2.0.35/2.1.63
ICP driver 1.02
from Kernel 2.0.36
ICP driver 1.07
from Kernel 2.2.0 (pre7)
ICP driver 1.10
G.3 Updating the driver using the driver sources
a)
Copy the driver sources to /usr/src/linux/drivers/scsi
(for a DOS disk for example with 'mcopy a:gdth.tgz')
b)
Unpack the archive with 'tar xvfz gdth.tgz
c)
Compile a new Kernel
(procedure depends on the Linux distribution, 'make config', 'make dep', 'make clean'
may become necessary before)
G.4 Driver installation or update using a patch
New installation of a driver patch:
a)
Copy the corresponding patch on the Linux system
(preferably to /usr/src/linux e.g. gdtp2036.gz for Linux 2.0.36)
Содержание GDT RS Series
Страница 2: ...2...
Страница 14: ...14 L 1 Technical Data of the ICP Controller 184 L 2 Boot Error Messages 184 L 3 Index 185...
Страница 15: ...15 Chapter A General General General General Information Information Information Information...
Страница 35: ...35 Chapter B Hardware Hardware Hardware Hardware Installation Installation Installation Installation...
Страница 40: ...40 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Страница 41: ...41 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Страница 47: ...47 Several internal Wide Ultra2 and Ultra 160 SCSI Hard Disks...
Страница 52: ...52...
Страница 53: ...53 Chapter C Quick Setup Quick Setup Quick Setup Quick Setup...
Страница 68: ...68 Replacement either manually or through hot fix method...
Страница 70: ...70...
Страница 71: ...71 Chapter D Using MS DOS Using MS DOS Using MS DOS Using MS DOS...
Страница 81: ...81 Chapter E Using NetWare Using NetWare Using NetWare Using NetWare...
Страница 88: ...88...
Страница 96: ...96...
Страница 97: ...97 Chapter G Using LINUX Using LINUX Using LINUX Using LINUX...
Страница 102: ...102...
Страница 103: ...103 Chapter H Using SCO UNIX Using SCO UNIX Using SCO UNIX Using SCO UNIX...
Страница 110: ...110...
Страница 111: ...111 Chapter I Using UnixWare Using UnixWare Using UnixWare Using UnixWare...
Страница 115: ...115 Chapter J ICP RAID Console ICP RAID Console ICP RAID Console ICP RAID Console ICPCON ICPCON ICPCON ICPCON...
Страница 147: ...147 Chapter K ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator...
Страница 182: ...182...
Страница 183: ...183 Chapter L Appendix Appendix Appendix Appendix...