76
buffers=30
stacks=9,256
dos=high,umb
shell=\COMMAND.COM /E:512 /P
device=\dos\setver.exe
device=\gdt\gdtaspi.exe
device=c:\corel\cuni_asp.sys /ID:6 /HAN:0 /N:1 /D:MSCD000
lastdrive=h
AUTOEXEC.BAT
path=c:\;c:\dos;c:\gdt;c:\aspi;
c:\corel\corelcdx /M:8 /D:MSCD000
The first line following the HIMEM.SYS command of the CONFIG.SYS file loads the
GDTX000.EXE. The next line loads the ICP ASPI Manager GDTASPI.EXE. Next, the corel
ASPI Module for the CDROM drive is loaded. The parameter "/D:MSCD000" has nothing to
do with a drive name, it only serves as recognition information for CORELCDX. As men-
tioned before, it is our objective to be able to access the CDROM drive with a drive name
(i.e., E). Naturally, this drive name has to be "free", and there has to be enough drive names
available. For example, the command LASTDRIVE=H would enable the user to use drive
names from A to H under DOS. In the AUTOEXEC.BAT file, the corel translation program for
CDROMs, CORELCDX, is loaded. The parameter /D:MSCD000 set here has to be identical to
the parameter set after the ASPI Module in the CONFIG.SYS file. After a warm reboot which
serves to activate the changes made in the CONFIG.SYS and AUTOEXEC.BAT files, the
CDROM drive can be accessed as drive E (in our example there are two SCSI hard disks in
the PCI computer, and under MS-DOS they are accessed as C and D). Drive E can be ac-
cessed under Windows, too, now (the Icon next to "E" indicates that it is a CDROM drive).
Information on the various CDROM drives which can be used can be obtained directly from
Corel.
D.6 The ICP ASPI Manager GDTASPI.EXE
The ICP ASPI Manager GDTASPI.EXE allows you not only to run
Not Direct Access Devices
(e.g.,
CDROMs, tapes, MODs etc.), but to control hard disks and removable hard disks, too (the
so-called
Direct Access Devices
). These devices are then no longer controlled by ICPCON but
exclusively by the ASPI interface. The advantage is evident, in particular with regard to re-
movable hard disks. When using an appropriate ASPI module to access these removable
hard disks, for example ASPIDISK.SYS or UNI_ASP.SYS from Corel, you can exchange the
media of these drives under DOS without having to use ICPCON. To the ASPI interface, the
ICP Controller appears as one host-adapter. If there are more SCSI controllers (even if from
various manufacturers) in the system and corresponding ASPI managers have been in-
stalled in the CONFIG.SYS file, you can determine a controller's host adapter number by
using the ICP program
ASPISCAN.EXE
. In order to exclude that a
Direct Access Device
is run
directly from the ICP Controller, it has to be reserved for the ASPI interface control. To do
so, certain parameters have to be specified when the ICP ASPI manager is loaded:
DEVICE=GDTASPI.EXE /R:Hx1Iy1[:Hx2Iy2:Hx3Iy3 ...]
H:
host adapter number
I:
SCSI ID of the SCSI device to be reserved
x1, y1:
host adapter number, SCSI ID
of the first SCSI device to be reserved
(in decimal form)
x2, y2:
host adapter number, SCSI ID
of the second SCSI device to be reserved
(in decimal form)
Содержание GDT RS Series
Страница 2: ...2...
Страница 14: ...14 L 1 Technical Data of the ICP Controller 184 L 2 Boot Error Messages 184 L 3 Index 185...
Страница 15: ...15 Chapter A General General General General Information Information Information Information...
Страница 35: ...35 Chapter B Hardware Hardware Hardware Hardware Installation Installation Installation Installation...
Страница 40: ...40 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Страница 41: ...41 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Страница 47: ...47 Several internal Wide Ultra2 and Ultra 160 SCSI Hard Disks...
Страница 52: ...52...
Страница 53: ...53 Chapter C Quick Setup Quick Setup Quick Setup Quick Setup...
Страница 68: ...68 Replacement either manually or through hot fix method...
Страница 70: ...70...
Страница 71: ...71 Chapter D Using MS DOS Using MS DOS Using MS DOS Using MS DOS...
Страница 81: ...81 Chapter E Using NetWare Using NetWare Using NetWare Using NetWare...
Страница 88: ...88...
Страница 96: ...96...
Страница 97: ...97 Chapter G Using LINUX Using LINUX Using LINUX Using LINUX...
Страница 102: ...102...
Страница 103: ...103 Chapter H Using SCO UNIX Using SCO UNIX Using SCO UNIX Using SCO UNIX...
Страница 110: ...110...
Страница 111: ...111 Chapter I Using UnixWare Using UnixWare Using UnixWare Using UnixWare...
Страница 115: ...115 Chapter J ICP RAID Console ICP RAID Console ICP RAID Console ICP RAID Console ICPCON ICPCON ICPCON ICPCON...
Страница 147: ...147 Chapter K ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator...
Страница 182: ...182...
Страница 183: ...183 Chapter L Appendix Appendix Appendix Appendix...