123
the SCSI channel
the SCSI-ID
the vendor and type
Retries/Reassigns, Grown Defects and the Last Status
(1) The
Retries
counter is incremented by one unit whenever the ICP Controller retries to ac-
cess a hard disk. If this counter continues to increase (possibly on other hard disks, too) it
is very likely that the cable is not
good
enough for the selected data transfer rate (cable too
long, poor quality of cable and connectors), or that the SCSI bus is not properly terminated
(too many terminators on the cable, or missing terminator). In very few cases is the hard
disk concerned defective. The retry counter also increases when the SCSI parameters of a
hard disk are changed (see further ahead). Obviously, retries due to this do not imply bad
cabling.
(2) The reassign counter reflects the number of media defects which occur on the hard disk
drive. Defective blocks of the hard disk are assigned substitute blocks (spare blocks) which
are either on the same track, or on alternate ones if all spare blocks on the same track are
already in use. The administration of the reassignments is carried out by the hard disk
through according reassignment tables. Note: If a hard disk works with alternate tracks, it
is generally no longer suitable for applications with high performance expectations. When-
ever a defective block is being accessed, the read/write actuator has to move to an alternate
position and this requires extra time.
If you observe that the number of reassigns is constantly increasing, you may suspect that
something is wrong with this drive.
(3) The Grown Defects counter shows the number of media defects which have occurred
since the first time the device was operated with an ICP Controller. A specific hard disk is in
a good condition when it has 0 grown defects. When this counter increases, there is defi-
nitely something wrong with the device.
(4) The Last Status information should always be 0x00000000. After a device failure or other
significant events, a different value may be displayed here. This value is volatile and is reset
to 0x00000000 after each power up and/or reset.
If you press ENTER on a Drive,
ICPCON display further informa-
tion on the SCSI parameter set-
tings.
J.3.4 Menu Monitor: Save Information
The
Save Information
option gives you the possibility to save the configuration information
regarding the selected ICP Controller and its devices in an ASCII-file. This may help if you
require support and is also good for your system documentation.
Содержание GDT RS Series
Страница 2: ...2...
Страница 14: ...14 L 1 Technical Data of the ICP Controller 184 L 2 Boot Error Messages 184 L 3 Index 185...
Страница 15: ...15 Chapter A General General General General Information Information Information Information...
Страница 35: ...35 Chapter B Hardware Hardware Hardware Hardware Installation Installation Installation Installation...
Страница 40: ...40 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Страница 41: ...41 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Страница 47: ...47 Several internal Wide Ultra2 and Ultra 160 SCSI Hard Disks...
Страница 52: ...52...
Страница 53: ...53 Chapter C Quick Setup Quick Setup Quick Setup Quick Setup...
Страница 68: ...68 Replacement either manually or through hot fix method...
Страница 70: ...70...
Страница 71: ...71 Chapter D Using MS DOS Using MS DOS Using MS DOS Using MS DOS...
Страница 81: ...81 Chapter E Using NetWare Using NetWare Using NetWare Using NetWare...
Страница 88: ...88...
Страница 96: ...96...
Страница 97: ...97 Chapter G Using LINUX Using LINUX Using LINUX Using LINUX...
Страница 102: ...102...
Страница 103: ...103 Chapter H Using SCO UNIX Using SCO UNIX Using SCO UNIX Using SCO UNIX...
Страница 110: ...110...
Страница 111: ...111 Chapter I Using UnixWare Using UnixWare Using UnixWare Using UnixWare...
Страница 115: ...115 Chapter J ICP RAID Console ICP RAID Console ICP RAID Console ICP RAID Console ICPCON ICPCON ICPCON ICPCON...
Страница 147: ...147 Chapter K ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator...
Страница 182: ...182...
Страница 183: ...183 Chapter L Appendix Appendix Appendix Appendix...