61
Select the menu option Configure Host Drives with ENTER.
The list of available Host Drives contains already an entry. There is a RAID 5 Host Drive.
After selecting Create new Host Drive ICPCON displays a list of “free” hard disks. These are
all the drives which do not belong to a Logical or Hosr Drive and can be used for new Host
Drives. Select a hard disk with the SPACE bar (it becomes marked with an "*") and press
ENTER.
Since we have only one hard disk selected, in the Choose Type
menu, the only possible (high-lighted) entry is Single Disk. Press
ENTER. For security reasons, you will be asked if you want to use
the selected disk to create a Host Drive.
As we are sure of our choice, we confirm with <Yes>.
ICPCON creates a new Host Drive now. All parameters of the hard
disk are adjusted automatically at optimum level.
Содержание GDT RS Series
Страница 2: ...2...
Страница 14: ...14 L 1 Technical Data of the ICP Controller 184 L 2 Boot Error Messages 184 L 3 Index 185...
Страница 15: ...15 Chapter A General General General General Information Information Information Information...
Страница 35: ...35 Chapter B Hardware Hardware Hardware Hardware Installation Installation Installation Installation...
Страница 40: ...40 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Страница 41: ...41 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Страница 47: ...47 Several internal Wide Ultra2 and Ultra 160 SCSI Hard Disks...
Страница 52: ...52...
Страница 53: ...53 Chapter C Quick Setup Quick Setup Quick Setup Quick Setup...
Страница 68: ...68 Replacement either manually or through hot fix method...
Страница 70: ...70...
Страница 71: ...71 Chapter D Using MS DOS Using MS DOS Using MS DOS Using MS DOS...
Страница 81: ...81 Chapter E Using NetWare Using NetWare Using NetWare Using NetWare...
Страница 88: ...88...
Страница 96: ...96...
Страница 97: ...97 Chapter G Using LINUX Using LINUX Using LINUX Using LINUX...
Страница 102: ...102...
Страница 103: ...103 Chapter H Using SCO UNIX Using SCO UNIX Using SCO UNIX Using SCO UNIX...
Страница 110: ...110...
Страница 111: ...111 Chapter I Using UnixWare Using UnixWare Using UnixWare Using UnixWare...
Страница 115: ...115 Chapter J ICP RAID Console ICP RAID Console ICP RAID Console ICP RAID Console ICPCON ICPCON ICPCON ICPCON...
Страница 147: ...147 Chapter K ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator...
Страница 182: ...182...
Страница 183: ...183 Chapter L Appendix Appendix Appendix Appendix...