162
Remote mounted Cluster Drive
A Cluster Drive is a Host Drive on a clustering I/O channel.
This Host Drive is mounted on an ICP Controller in a different server.
Clustering means that two or more servers share resources. In case of one server failing
these resources move over to another valid server. The hard disks used for clustering are
physically not connected with just one ICP Controller, but with several ICP Controllers in
different servers (shared I/O channels).
Only one server can own a Host Drive at the same time, so a Host Drive configured for clus-
tering may either be controlled by the selected ICP Controller (i.e., local mounted) or by a
different ICP Controller (i.e., remote mounted).
You may only change the configuration of a local mounted Host Drive.
Private Host Drive belonging to another ICP Controller
This is a Host Drive on a clustering I/O channel.
This Host Drive is configured as a Private Host Drive and does not belong to the
selected ICP Controller.
Clustering means that two or more servers share resources. In case of one server failing
these resources move over to another valid server. The hard disks used for clustering are
physically not connected with just one ICP Controller, but with several ICP Controllers in
different servers (shared I/O channels).
Usually, when booting a cluster, the ICP Controller starting up first will gain control over all
Host Drives on the clustering I/O channels. If you want to be sure that a Host Drive is con-
trolled by a specific server, you may configure this Host Drive as a Private Host Drive. A Pri-
vate Host Drive cannot be used for clustering anymore.
Note:
You cannot change the configuration of a Private Host Drive which is not property of
the selected ICP Controller. You have to use ICPCON to change its configuration.
A Private Host Drive belonging to the selected ICP Controller will be displayed like a normal
Host Drive.
Array Drives
Array Drives or RAID drives consist of Logical Drives. They can be fault tolerant, depending
on the RAID level. The RAID level is displayed under the Array Drive icon.
Click on the icons to get more information on the different states of an array.
Icon
Description
double click opens... right click
opens...
RAID 4/5/10
Idle
Build
Ready
Fail
Error
Array Drive
Information
Содержание GDT RS Series
Страница 2: ...2...
Страница 14: ...14 L 1 Technical Data of the ICP Controller 184 L 2 Boot Error Messages 184 L 3 Index 185...
Страница 15: ...15 Chapter A General General General General Information Information Information Information...
Страница 35: ...35 Chapter B Hardware Hardware Hardware Hardware Installation Installation Installation Installation...
Страница 40: ...40 Example for a SCSI Flat Ribbon Cable for 8 Bit SCSI Devices narrow...
Страница 41: ...41 Example for a SCSI Flat Ribbon Cable for 16 Bit SCSI Devices wide...
Страница 47: ...47 Several internal Wide Ultra2 and Ultra 160 SCSI Hard Disks...
Страница 52: ...52...
Страница 53: ...53 Chapter C Quick Setup Quick Setup Quick Setup Quick Setup...
Страница 68: ...68 Replacement either manually or through hot fix method...
Страница 70: ...70...
Страница 71: ...71 Chapter D Using MS DOS Using MS DOS Using MS DOS Using MS DOS...
Страница 81: ...81 Chapter E Using NetWare Using NetWare Using NetWare Using NetWare...
Страница 88: ...88...
Страница 96: ...96...
Страница 97: ...97 Chapter G Using LINUX Using LINUX Using LINUX Using LINUX...
Страница 102: ...102...
Страница 103: ...103 Chapter H Using SCO UNIX Using SCO UNIX Using SCO UNIX Using SCO UNIX...
Страница 110: ...110...
Страница 111: ...111 Chapter I Using UnixWare Using UnixWare Using UnixWare Using UnixWare...
Страница 115: ...115 Chapter J ICP RAID Console ICP RAID Console ICP RAID Console ICP RAID Console ICPCON ICPCON ICPCON ICPCON...
Страница 147: ...147 Chapter K ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator ICP RAID Navigator...
Страница 182: ...182...
Страница 183: ...183 Chapter L Appendix Appendix Appendix Appendix...