![ICP DAS USA tM-TH8 Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/icp-das-usa/tm-th8/tm-th8_user-manual_3864813097.webp)
tM-TH8 User Manual, Rev: A1.1 7MH-018-A11
97
2.33 @AASxTttC(data)
Description:
Sets the Steinhart coefficient of a user-defined type.
Syntax:
@AASxTttC(data)[CHKSUM](CR)
@
Delimiter character
AA
Address of the module to be set (00 to FF)
S
Command to set the Steinhart coefficient
x
A: sets Steinhart coefficient A
B: sets Steinhart coefficient B
C: sets Steinhart coefficient C
Ttt
tt represents the type code of the user-defined
type to set the Steinhart coefficient.
C(Data) The (Data) is eight hexadecimal digits in IEEE-
754 format to represent the Steinhart coefficient.
See Section 1.11 for details.
Response:
Valid command:
!AA[CHKSUM](CR)
Invalid command:
?AA[CHKSUM](CR)
!
Delimiter character for a valid command
?
Delimiter character for an invalid command or
invalid type code
AA
Address of the responding module (00 to FF)
There will be no response if the command syntax is
incorrect, there is a communication error, or there is no
module with the specified address.
tM-TH8
Содержание tM-TH8
Страница 8: ...tM TH8 User Manual Rev A1 1 7MH 018 A11 8 1 2 Terminal Assignment...
Страница 10: ...tM TH8 User Manual Rev A1 1 7MH 018 A11 10 1 4 Block Diagrams 1 4 1 Block Diagram for the tM TH8...
Страница 11: ...tM TH8 User Manual Rev A1 1 7MH 018 A11 11 1 5 Dimensions...
Страница 13: ...tM TH8 User Manual Rev A1 1 7MH 018 A11 13 1 7 Quick Start Please refer to the Quick Start Guide for tM TH8...
Страница 67: ...tM TH8 User Manual Rev A1 1 7MH 018 A11 67 Related Topics Section 1 9 Calibration tM TH8...