I-7530A-MR Modbus RTU to CAN
Converter User’s Manual (Version 1.07, 06/2016) ------------- 53
Send a CAN message with a standard remote frame. ID=2E8,
DLC=8.
4.3 eIIIIIIIILDD
…[CHK]<CR>
Description:
Send or receive an extended CAN data frame.
Syntax: eIIIIIIIILDD
…[CHK]<CR>
e
Stands for the extended (2.0B) data frame.
IIIIIIII
29 bits Identifier (00000000~1FFFFFFF)
L
Data length (0~8)
DD
…
Input data frame value according to the data length (00~FF)
Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the
“Error Response” function while using
the UART2CAN Utility in order to receive Syntax and/or communication
error information.
Example:
Command: e1234567851122334455<CR>
Send a CAN message with an extended data frame. ID=12345678,
DLC=5, data1=11, data2=22, data3=33, data4=44 and data5=55.
4.4 EIIIIIIIIL[CHK]<CR>
Description:
Send or receive an extended CAN remote frame.
Syntax: EIIIIIIIIL[CHK]<CR>
E
Stands for the extended (2.0B) CAN remote frame.
IIIIIIII
29 bits Identifier (00000000~1FFFFFFF)
L
Data length (0~8)
Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the
“Error Response” function while using