I-7530A-MR Modbus RTU to CAN
Converter User’s Manual (Version 1.07, 06/2016) ------------- 54
the UART2CAN Utility in order to receive Syntax and/or communication
error information.
Example:
Command: E010156786<CR>
Send a CAN message with an extended remote frame.
ID=01015678, DLC=6.
4.5 S[CHK]<CR>
Description:
Read the I-7530A-MR CAN baud rate and error flag message.
Syntax: S[CHK]<CR>
S
Command character.
Response:
Valid Command: !CFFTTRRO[CHK]<CR>
Invalid command: ?<Error Code>[CHK]<CR>
!
Delimiter for valid command
C
current baud rate setting of CAN
FF
CAN status register
TT
CAN transmit error counter
RR
CAN receive error counter
O
CAN or RS-232/485/422 FIFO Overflow flag
Note:
It is necessary to enable the
“Error Response” function while using
the UART2CAN Utility in order to receive Syntax and/or communication
error information. Furthermore, all response results are shown in the ASCII
format. Users need to make an ASCII to hex format transformation in order
to understand what the meaning is. The following table shows all the
indications of the response of this command.
Table 4-2: CAN baud rate list
AsciiToHex(C)
Description
0
10K baud rate of CAN
1
20K baud rate of CAN
2
50K baud rate of CAN
3
100K baud rate of CAN