JP1 ~ JP3
Jumper 1~3(Fig 1-4) controls the input voltage of LTC for 24V (Jumper position is in
1~2) or 5V (Jumper position is in 2~3). The default setting is 5V.
Fig. 1-4 Jumper 1~ Jumper 3 setting
JP4 ~ JP6
The encoder signals can be chosen from servo driver encoder or external encoder.
Fig. 1-5 shows that the encoder signals are selected from servo driver encoder
(default setting). Fig. 1-6 shows that the encoder signals are selected from external
encoder.
Fig. 1-5 Primary encoder signals setting
Fig. 1-6 External encoder signals setting
http://www.icpdas.com
DN-8368MB User Manual
V 1.0
16