INSTALLATION AND CONNECTIONS
■
Wiring the EX-2780 system cable
CAUTION:
NEVER
cut the supplied system cable.
q
Loosen the four bolts on the bottom of the scanner
unit body using the supplied allen wrench (
q
), and
open the top cover. (
w
)
w
Loosen the sealing nut on the scanner unit and pass
the system cable through the sealing nut and sealing
tube. (
e
)
e
Connect the power cable (black and red) connec-
tor to the power unit connector through the looped
cable tie. (
r
)
r
Insert the PA cable (black and white) connector into
the PA unit connector. Be sure to follow the diagram
below carefully. (
t
)
• Secure the looped PA cable with the looped cable tie.
(
y
)
t
Connect the shielded cable ground wire to the chas-
sis with the screw, as shown in the diagram. (
u
)
y
Clamp the system cable with the cable clamp metal
fitting using a screw near the sealing connector.
(
i
)
Be sure to clamp it tightly.
u
Clamp the system cable with the ferrite EMI filter at-
tached near the sealing connector. (
o
)
Be sure to clamp it tightly.
Secure the ferrite EMI filter with cable tie.
i
Tighten the sealing-nut, then close the top cover.
DO NOT
stretch the system cable too much, other-
wise a miss contact of the connector may occur.
o
Tighten the four bolts on the bottom of the scanner
body. (Use a torque wrench to 9.8 N•m; 7.23 lbf•ft.)
Allen wrench
Scanner body
Fig. 1
q
w
Ferrite EMI filter Cable tie
Cable clamp
i
o
Sealing tube
Sealing Nut
e
Fig. 2
Fig. 3
Shielded cable
ground wire
System cable
u
r
t
Looped
cable tie
Power cable
PA cable
y