24
3
BASIC OPERATION
■
Bearing setting
The radar bearing interface accepts NMEA, N+1, AUX,
or COG data format and the bearing can use a mag-
netic or true north type. When a true north type bear-
ing is used, the variation from magnetic north can be
adjusted on 0.1˚ steps.
D
Setting the bearing type
q
Push [MENU]/[
], and then push [
t
] or [
u
] to
select the System menu.
w
Push [
p
] or [
q
] to select the “Bearing Mode” item.
e
Push [ENTER]/[
] to enter the option selection
mode.
r
Push [
p
] or [
q
] to select the Bearing mode.
• True and Magnetic north type are selectable.
• All displayed bearing readouts show the selected bear-
ing type.
t
Push [ENTER]/[
] to save the setting.
y
Push [MENU]/[
] to exit the Menu screen.
D
Setting the magnetic variation
q
Push [MENU]/[
], and then push [
t
] or [
u
] to
select the System menu.
w
Push [
p
] or [
q
] to select the “Variation” item.
e
Push [ENTER]/[
] to enter the option selection
mode.
r
Push [
p
] or [
q
] to select the bearing variation.
• “Auto”* and “Manual” are selectable.
t
Push [ENTER]/[
] to save the setting.
y
When the “Manual” option is selected in step
r
,
push [
q
] to select the “Manual Variation,” then push
[ENTER]/[
].
u
Push [
p
] or [
q
] to set the bearing variation.
i
Push [ENTER]/[
] to save the setting.
o
Push [MENU]/[
] to exit the Menu screen.
*
NOTE:
• NMEA data is required for the Auto variation.
NEV-
ER
select “Auto” without NMEA data or incorrect
variation data may be entered.
• Until an effective variation is received, use 0° for
difference between true North and magnetic North.
After an effective variation is received, use the last
data for the difference. The MR-1210 memorize
the data until you turn OFF the power.
T: True north
M: Magnetic north
(MENU > System >
Bearing Mode
)
(MENU > System >
Variation
)