SCAN OPERATION
■
Skip channel setting
The memory skip function speeds up scanning by checking
only those memory channels not set as skip channels. Set
skip channels as follows.
q
Select a memory channel:
➥
Push
[M/CALL•PRIO]
to select memory mode.
➥
Rotate
[DIAL]
to select the desired channel to be a skip
channel.
w
Push
[SET•LOCK]
to enter set mode.
• Rotate
[DIAL]
to select “SET,” if “CALLS” or “MESSAG” is dis-
played.
e
Push
[SET•LOCK]
or
[S.MW•MW]
several times until
“CHS” appears as shown above.
r
Rotate
[DIAL]
to turn the skip function ON or OFF for the
selected channel.
• “
~
” appears (CHS-ON); The channel is skipped during scan.
• “P
~
” appears (CHS-ON); The channel is skipped during scan
and the programmed frequency is skipped during VFO scan,
such as programmed scan.
• “
~
” disappears (CHS-OF); The channel is scanned during
scan.
t
Push any key below the display to exit set mode.
[
z
Select a memory channel.
➥
Select memory mode by pushing
[MR/CALL]
.
➥
Push
[
Y
Y
]
or
[
Z
Z
]
to select the desired channel
to be a skip channel.
• Direct memory channel selection is also available.
x
Push
[
SET
B(D-OFF)]
to enter set mode.
• Push
[
Y
Y
]
or
[
Z
Z
]
to select “SET,” if necessary.
c
Push
[
SET
B(D-OFF)]
or
[
ENT
C(T-OFF)]
several
times until “CHS” appears as shown at left.
v
Push
[
Y
Y
]
or
[
Z
Z
]
to set or cancel the skip setting.
• See item
r
at left for skip indicator details.
b
Push
[
CLR
A(MW)]
to exit set mode.
SET
B
The display shows that mem-
ory channel 16 is set as a skip
channel.
ID-800H_1.qxd 2007.06.14 3:09 PM Page 47