Remote Control function
R-5
• DV RX call sign setting
Command:
20 0001
,
20 0002
q
Header flag data
(First byte)
Data
Description
bit7
(0: Fixed)
—
bit6
(0: Fixed)
—
bit5
(0: Fixed)
—
bit4
0/1
0= Voice, 1= Data
bit3
0/1
0= Direct, 1= Through repeater
bit2
0/1
0= No Break-in, 1= Break-in
bit1
0/1
0= Data, 1= Control
bit0
0/1
0= Normal, 1= EMR
w
Header flag data
(Second byte)
Data
Description
bit2 bit1 bit0
1
1
1
Repeater control
1
1
0
Send auto acknowledge
1
0
1 (Not used)
1
0
0
Request to re-transmit
0
1
1 Send acknowledge
0
1
0
Receive no reply
0
0
1 Repeater disabled
0
0
0
NULL
e
~
!0
: Call sign of the caller station
(8 characters, fixed)
!1
~
!4
: Note of the caller station
(4 characters, fixed)
!5
~
@2
: Call sign of the called station
(8 characters, fixed)
@3
~
#0
: Call sign of the Access/Area repeater (R1)
(8 characters, fixed)
#1
~
#8
: Call sign of the Link/Gateway repeater (R2)
(8 characters, fixed)
L
FF: When no call sign receiving after turning ON the
transceiver.
• DV RX message
Command:
20 0101
,
20 0102
X X
X
X
X
X
X X
@1
~
@8
@9
~
#2
• • •
X X
• • •
X X
q
~
@0
q
~
@0
: Message (20 characters)
@1
~
@8
: Call sign of the caller station (8 characters)
@9
~
#2
: Note of the caller station (4 characters)
L
FF: When no call sign receiving after turning ON the
transceiver.
Example:
Gateway call
JM1ZLK calling from
JP1YIU port
A...
JM1ZLK calling from
JP1YIU port
A...
JM1ZLK calling from
JP1YIU port
A...
JM1ZLK calling from
JP1YIU port
A...
RXRPT2
RXRPT1
CALLER
GW
INTERNET
INTERNET
CALLED
Your station
JM1ZLK calling from
JP1YIU port A...
CALLER: Caller’s call sign
CALLED: Called station call sign
RXRPT1: Call sign of the repeater that was accessed by the
caller station.
L
If it was a call through a gateway and the Internet,
the
gateway call sign of the repeater your received the
call from.
RXRPT2: Call sign of the repeater you received the call
from.
• DV RX Status setting
Command:
20 0201
,
20 0202
Data
Function
Description
bit7
0
(Fixed)
—
bit6
0/1
Receiving a
voice call
While receiving a digital
voice signal, select “1.”
(Regardless of the DSQL and
CSQL setting)
bit5
0/1 Last call finisher When you finish the last call,
select “1.”
bit4
0/1
Receiving a
signal
When the audio tone can be
heard, select “1.”
bit3
0/1
Receiving a BK
call
While receiving a BK call,
select “1.”
bit2
0/1
Receiving a
EMR call
While receiving a EMR call,
select “1.”
bit1
0/1
Receiving a
signal other
than DV
When “DV” and “FM” are
blinking, select “1.”
bit0
0/1 Packet loss
status
While displaying a packet
loss.
Remote control (CI-V) information