background image

© 2017 Raymarine UK Limited

Document number: 88072-1

Date: 06-2017

English (en-US)

RV-2xx 3D Bronze Through-Hull Transducer

Installation instructions

REALVISION

Summary of Contents for Realvision RV-220P

Page 1: ...2017 Raymarine UK Limited Document number 88072 1 Date 06 2017 English en US RV 2xx 3D Bronze Through Hull Transducer Installation instructions REALVISION...

Page 2: ......

Page 3: ...s and refer to the separate warranty document packed with your product Warning High voltages This product may contain high voltages Do NOT remove any covers or otherwise attempt to access internal com...

Page 4: ...roduct online You should retain the label for future reference Product disposal Dispose of this product in accordance with the WEEE Directive The Waste Electrical and Electronic Equipment WEEE Directi...

Page 5: ...no Part no Description Hull geometry RV 20 0 A804 65 RealVision 3D Bronze Thru Hull Transducer 0 single all in one Hull with 0 flat bottom to 6 deadrise angle RV 21 2P A804 66 Hull with 6 to 18 deadri...

Page 6: ...ilot holes 4 9 mm inch drill bit for drilling anti rotation bolt hole 5 Half round file 6 75 mm 3 inch wrench spanner or suitable size adjustable wrench spanner 7 Marine grade sealant non acetate base...

Page 7: ...y Multiple transducers Note If you are installing a split pair of transducers for example an RV 212P unit with an RV 212S unit ensure that you test both transducers together by connecting them to the...

Page 8: ...the length of the hull measured along the waterline 5 Keel sailboat Fin keel mount forward of the keel ensuring that the keel will not obstruct the transducers wide beam width 6 Keel sailboat Full kee...

Page 9: ...ansducers the correct transducer port or starboard must be installed in the matching port or starboard side of the hull each transducer in a split pair has a label on the attached cable and markings a...

Page 10: ...devices Transducer dimensions RV 2xx All transducers in the RV 2xx series have the same external dimensions Dimension Measurement A 72 7mm 2 86 in B 60 0 mm 2 36 in C 85 0 mm 3 35 in D 8 0 mm 0 31 in...

Page 11: ...Wooden hulls may be susceptible to shrinkage if the vessel is removed from the water for an extended period followed by swelling when the vessel is returned to the water To avoid leaks or damage to th...

Page 12: ...Lower the transducer away from the hull while keeping the cable threaded through the hull and remove the mounting template ensure that the transducer is still supported from beneath 14 Carefully remo...

Page 13: ...revent leaks and transducer movement ensure that the nut is adequately tightened You should see the sealant protruding from the edges of all applied surfaces Important Do NOT overtighten Overtightenin...

Page 14: ...ant on the outside of the hull 33 Ensure that the sealant has fully cured before putting the vessel back in the water Refer to the sealant manufacturer s instructions for curing times 34 Once the vess...

Page 15: ...extension cable to connect the transducers to your multifunction display The following optional extension cables are available RealVision transducer extension cable 3 m 9 8 ft part number A80475 Real...

Page 16: ...ute the cable all the way to its destination before attaching the locking collar 1 Slide the locking collar over the end of the connector then push it towards the cable end of the connector Important...

Page 17: ...des easily for approximately 1 cm onto the connector before butting up against the connector moulding 3 Carefully insert the pointed end of the supplied tool into the split ring s gap labelled C in th...

Page 18: ...to attach it without using the tool 4 Use the tool to gently lever the split ring over the moulding on the connector until it snaps into position approximately 0 5 cm further back towards the cable en...

Page 19: ...19...

Page 20: ...lled D in the illustration pass through the channels labelled E in the split ring The locking collar slides easily towards the plug end of the connector before butting up against the split ring mouldi...

Page 21: ...ted to the correct Y cable tail ii Connect an extension cable to the remaining free plug on the Y cable See RealVision 3D transducer extension cable 4 Ensuring correct orientation push the transducer...

Page 22: ...instructions 1 Transducer connector 2 The supplied cable ties should be used to secure the ferrite in position 3 Fit the supplied ferrite to the transducer cable ensuring a tight fit The ferrite shoul...

Page 23: ......

Page 24: ...Raymarine Marine House Cartwright Drive Fareham Hampshire PO15 5RJ United Kingdom Tel 44 0 1329 246 700 www raymarine com a brand by...

Reviews: