Command table (continued)
D
Cmd. Sub
cmd.
Data
Description
1A
05 0089
00
LSB selection for CW normal side set
01
USB selection for CW normal side set
0090
00
SHARP selection for APF type
01
SOFT selection for APF type
0091
00
Voice memory transmission OFF with
external keypad
01
Voice memory transmission ON with external
keypad
0092
00
Memory keyer transmission OFF with
external keypad
01
Memory keyer transmission ON with external
keypad
0093
00
RTTY memory transmission OFF with
external keypad
01
RTTY memory transmission ON with external
keypad
0094
00
PSK memory transmission OFF with external
keypad
01
PSK memory transmission ON with external
keypad
0095
00
Voice memory transmission OFF with
[F1]–[F4] on the keyboard
01
Voice memory transmission ON with [F1]–
[F4] on the keyboard
0096
00
Memory keyer transmission OFF with
[F1]–[F4] on the keyboard
01
Memory keyer transmission ON with [F1]–
[F4] on the keyboard
0097
00
CI-V transceive OFF
01
CI-V transceive ON
0098
00
CI-V selection for [USB-B] usage
01
Decode selection for [USB-B] usage
0099
00
300 bps selection for decode speed
01
1200 bps selection for decode speed
02
4800 bps selection for decode speed
03
9600 bps selection for decode speed
04
19200 bps selection for decode speed
0100
00
English keyboard selection
01
Japanese keyboard selection
02
United Kingdom keyboard selection
03
French keyboard selection
04
French (Canadian) keyboard selection
05
German keyboard selection
06
Portuguese keyboard selection
07
Portuguese (Brazilian) keyboard selection
08
Spanish keyboard selection
09
Spanish (Latin American) keyboard selection
10
Italian keyboard selection
0101
0010 to
0100
Send/read keyboard repeat delay
( 0010=100 milliseconds,
0100=1000 milliseconds
50 millisecond steps)
0102 00 to 31 Send/read keyboard repeat speed
(00=2.0 cps, 31=30.0 cps)
0103
00
Scope indication during TX OFF
01
Scope indication during TX ON
0104
00
Scope max. hold function OFF
01
Scope max. hold function ON
0105
00
Filter center selection for scope center
frequency (center mode only)
01
Carrier point center selection for scope
center frequency (center mode only)
02
Carrier point center (Abs. Freq.) selection for
scope center frequency (center mode only)
0106 see p. 167 Send/read waveform color for receiving
signal
0107 see p. 167 Send/read waveform color for max. hold
0108
00
SLOW selection for scope sweep speed in
±2.5 kHz span
01
MID selection for scope sweep speed in
±2.5 kHz span
02
FAST selection for scope sweep speed in
±2.5 kHz span
Cmd. Sub
cmd.
Data
Description
1A
05 0109
00
SLOW selection for scope sweep speed in
±5 kHz span
01
MID selection for scope sweep speed in
±5 kHz span
02
FAST selection for scope sweep speed in
±5 kHz span
0110
00
SLOW selection for scope sweep speed in
±10 kHz span
01
MID selection for scope sweep speed in
±10 kHz span
02
FAST selection for scope sweep speed in
±10 kHz span
0111
00
SLOW selection for scope sweep speed in
±25 kHz span
01
MID selection for scope sweep speed in
±25 kHz span
02
FAST selection for scope sweep speed in
±25 kHz span
0112
00
SLOW selection for scope sweep speed in
±50 kHz span
01
MID selection for scope sweep speed in
±50 kHz span
02
FAST selection for scope sweep speed in
±50 kHz span
0113
00
SLOW selection for scope sweep speed in
±100 kHz span
01
MID selection for scope sweep speed in
±100 kHz span
02
FAST selection for scope sweep speed in
±100 kHz span
0114
00
SLOW selection for scope sweep speed in
±250 kHz span
01
MID selection for scope sweep speed in
±250 kHz span
02
FAST selection for scope sweep speed in
±250 kHz span
0115 see p. 167 Scope edge frequencies for 0.03 to
1.60 MHz band
0116 see p. 167 Scope edge frequencies for 1.60 MHz to
2.00 MHz band
0117 see p. 167 Scope edge frequencies for 2.00 MHz to
6.00 MHz band
0118 see p. 167 Scope edge frequencies for 6.00 MHz to
8.00 MHz band
0119 see p. 167 Scope edge frequencies for 8.00 MHz to
11.00 MHz band
0120 see p. 167 Scope edge frequencies for 11.00 MHz to
15.00 MHz band
0121 see p. 167 Scope edge frequencies for 15.00 MHz to
20.00 MHz band
0122 see p. 167 Scope edge frequencies for 20.00 MHz to
22.00 MHz band
0123 see p. 167 Scope edge frequencies for 22.00 MHz to
26.00 MHz band
0124 see p. 167 Scope edge frequencies for 26.00 MHz to
30.00 MHz band
0125 see p. 167 Scope edge frequencies for 30.00 MHz to
45.00 MHz band
0126 see p. 167 Scope edge frequencies for 45.00 MHz to
60.00 MHz band
0127
00
Auto monitor function OFF during voice
memory transmission
01
Auto monitor function ON during voice
memory transmission
0128 03 to 10 Send/read voice memory short play time
(03=3 seconds, 10=10 seconds)
0129 05 to 15 Send/read voice memory normal record time
(05=5 seconds, 15=15 seconds)
0130
00
Normal selection for contest number style
01
“190
→
ANO” selection for contest number
style
02
“190
→
ANT” selection for contest number
style
03
“90
→
NO” selection for contest number style
04
“90
→
NT” selection for contest number style
163
12