We Think of Customer Satisfactio
n
Electrical Connection -
Junction Box Type
•
Usually an electrical permit and services of a licensed electrician are required.
•
The maximum allowable voltage variation is ±10 percent of the nameplate
rating.
•
On single phase models, the green/yellow lead must be connected to the
neutral conductor of the power source.
NOTICE! Miswiring may result
in damage to the icemaker.
•
The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size
conduit.
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire this unit could
result in death, serious injury, or severe damage
to the icemaker.
The white lead must be connected to the netural
of the power source.
See diagram below.
•
Electrical connection must be hard-wired and must meet national, state,
and local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, fire, or damage.
•
The icemaker requires an independent power supply of proper
capacity. See the nameplate for electrical specifications.
Failure to use an independent power supply of proper capacity can result
in a tripped breaker, blown fuse, damage to existing wiring, or component
failure. This could lead to heat generation or fire.
•
THE ICEMAKER MUST BE GROUNDED.
Failure to properly ground
the icemaker could result in death or serious injury.
•
Electrical connection must be made in accordance with the instructions
on the "WARNING" tag.