9. Type of Product Error
Type of
Error
Display
Cause
What to DO
Release
Action
Front Indicator
Lamp
FND
Module
(Option
Full Bin
-
The bin is filled with ice.
Use of ice
Automatically
release when the
bin is emptied.
Stop
Water
Supply
Trouble
Er15
Water for making ice is not
supplied within the required
time. (Maximum 5 minutes or
less)
Check water
supply
connection
Reconnect power
after resolving water
supply problem.
Stop
Water
Level
Sensor
Trouble
Er16
It flickers when the water
level sensor (high/low level)
detects the water level as
the ice maker enters harvest
mode after making ice.
- Check
water supply
connection
- Clean/
replace
water level
sensor
Replace water
level sensor and
reconnect power
after resolving water
supply problem.
Stop
Trouble
in Ice
Making
Er01
When the outlet temperature
of the evaporator reaches
0℃ 30 minutes after the ice
making started.
Check cooling
unit
(Inquire Service
Center)
Reconnect power
after resolving
cooling problem.
Stop
Poor Ice
Making
Er03
When the outlet temperature
of the evaporator reaches
exceeds -5℃ 30 minutes
after the ice making started.
Check cooling
unit
(Inquire Service
Center)
Reconnect power
after resolving
cooling problem.
Run
Ice
Making
Delay
Er11
It flickers when the maximum
ice-making time (65 minutes)
is exceeded.
Check cooling
unit
(Inquire Service
Center)
- Clean ice
thickness sensor
- Reconnect
power after
resolving
cooling problem
Stop
(3
consecutive
Times)
Ice
Harvest
Delay
Er12
It flickers when the maximum
harvest time (5 minutes) is
exceeded.
Check cooling
unit
(Inquire Service
Center)
- Clean/inspect
water curtain
and right magnet
detection unit
- Reconnect
power after
resolving
cooling problem
Stop
(3
consecutive
Times)
High
Pressure
Detection
Er13
The water does not cool
down the gas (HIGH
PRESSURE S/W
is open).
Check water
supply line of
the cooling
unit
(Inquire
Service Center
when there is
a problem)
Reconnect power
after resolving the
cooling water
supply problem.
Stop
High
Pressure
Detection
(3
Consecutive
Times)
Er14
Excessive
Cooling
Water
Supply
Er17
The water valve on the
cooling
unit (condenser) is
malfuncioning.
Run
Drainage
error
Er18
The sump water does not
drain.
Check drain valve
and drain line.
Check water level
sensor.
Reconnect power
after resolving
cooling problem.
Stop
Содержание IM-0350-AC